3/32 E7018 Amperage: Settings, Polarity & How to Run It
My first E7018 rod went about as badly as a weld can go without catching fire. I was…
READ ARTICLE →You stand in front of the rod rack at the supply house, staring at boxes labeled E6013, E7018, E6010, and ER70S-6, with no idea which one will actually hold your gate together without cracking. Pick the wrong electrode and you can waste a weekend, warp the part, or leave a repair that fails under load. Picking the wrong electrode is one of the fastest ways to ruin a weld, waste money, and turn a simple repair into a rework job. The codes on those boxes are not random, though. They follow a system you can learn in an afternoon.
Before we decode anything, let’s settle the vocabulary. In welding, rod and electrode are not interchangeable, even though most of us blur them in everyday talk.
According to the American Welding Society’s A3.0 standard, an electrode is “a component of the welding circuit through which current is conducted and that terminates at the arc, molten conductive slag, or base metal.” A rod, the same standard says, is “a form of welding filler metal, normally packaged in straight lengths, that does not conduct the welding current.”
That single difference explains the whole family. A stick electrode for shielded metal arc welding (SMAW) is consumable: it carries the current, then melts and becomes part of the weld. TIG is different. The tungsten electrode holds the arc but never melts, so you add a separate bare rod by hand. Knowing which role a product plays keeps you from grabbing the wrong item.
In day-to-day talk, “welding rod” gets stretched to cover almost anything that feeds a joint: SMAW stick electrodes, TIG filler rods, and the solid or flux-cored wires that spool through a MIG gun. Those spooled options follow their own rules, which is why wire selection deserves a dedicated look in our MIG welding wires types and sizes guide.
The electrode you select sets four things at once: strength, penetration, position capability, and cost. Get it wrong and you risk under-matched weld strength, poor penetration, or hydrogen cracking, a defect that can surface days after the weld looks perfectly fine.
Quick Note: The governing AWS specification for mild steel stick electrodes is AWS A5.1, Carbon Steel Electrodes for Shielded Metal Arc Welding. If you memorize one document, make it that one.
Everything that follows hangs on the AWS filler metal classification system, the shared language printed on every box and spool. We will decode those numbers, compare the major carbon steel families, unpack flux coatings, cover specialty alloys, and examine the spooled choices. The Hobart electrode classification reference is a handy companion as you go. By the end, you will be able to walk up to that rack, read the label, and choose the rod that fits your steel, position, and budget.
The string of characters stamped on a filler metal box isn’t random. It follows the AWS classification system, a compact shorthand that tells you an electrode’s strength, position, coating, and current type before you strike an arc. Decode it and the rack at the supply house stops being a guessing game.
Stick electrodes carry an E prefix, which means the filler conducts the current and is itself a consumable electrode — unlike a bare TIG rod or the wire used in MIG welding wires.
After the E come the strength digits, which always represent minimum tensile strength in ksi (thousands of pounds per square inch). In a four-digit code like E6013, the first two digits (60) mean 60,000 psi. In a five-digit code like E10018, the first three digits (100) mean 100,000 psi. So E70XX equals 70,000 psi, and E10018 delivers 100,000 psi. Match that number to your base metal’s strength.
The third digit tells you which positions the rod can handle:
An all-position rod like E6010 costs more because its fast-freezing slag has to perform overhead without dripping. A flat-only rod like E7024 is cheaper and lays metal fast, but it’s useless on a vertical joint.
The final digit encodes the flux coating chemistry plus the current and polarity the rod runs best on, which in turn drives penetration. Here’s the full 0–9 breakdown:
| Digit | Coating Type | Current / Polarity | Penetration |
|---|---|---|---|
| 0 | High cellulose sodium | DCEP | Deep |
| 1 | High cellulose potassium | AC or DCEP | Deep |
| 2 | High titania sodium | AC or DCEN | Medium |
| 3 | High titania potassium | AC, DCEN, or DCEP | Shallow |
| 4 | Iron oxide titania | AC, DCEN, or DCEP | Medium |
| 5 | Low hydrogen sodium | DCEP | Medium |
| 6 | Low hydrogen potassium | AC or DCEP | Medium |
| 7 | High iron oxide | AC or DCEN | Medium |
| 8 | Low hydrogen potassium + iron powder | AC or DCEP | Medium |
| 9 | Iron oxide, titania, potassium | AC or DCEP | Medium |
Quick Note: The last digit is really two codes in one — coating family and compatible current. A rod rated for DCEP only won’t run cleanly on AC, no matter how you set the machine.
Polarity matters here. Run a DCEP-only rod on DCEN and you’ll get a cold, spattery bead, so polarity and amperage must match the coating — see our guide to 3/16 E7018 amperage, settings, and technique. The same logic carries into wire processes, as polarity for flux core welding: DCEN vs DCEP explains.
Extra letters and numbers after the core classification add important detail:
These designators aren’t decoration. On high-strength or restrained joints, the hydrogen limit is the difference between a sound weld and one that cracks overnight. The AWS filler metal specifications spell out exactly what each suffix must pass.
Low-alloy steel electrodes add a dash and a letter to flag their alloying elements, as on a rod like E8018-B2:
Pick the suffix that matches your base metal’s alloy; the wrong one can under-match strength or lose corrosion resistance.
Stainless electrodes break the pattern. Instead of tensile strength, the first three digits name the AISI stainless steel type. In E308L-16, “308L” is the alloy (a low-carbon 308), and the “-16” suffix gives position and current — here all-position on AC or DCEP. Switch it to “-15” and you get the same alloy in a DCEP-only coating. The Hobart electrode guide untangles the rest.
If you weld with a stick machine, these four electrodes cover almost everything you’ll do outside code work. They are the general-purpose carbon steel rods, and the main thing separating them is coating chemistry. Once you understand that, the rod rack stops being intimidating. Each box follows the same AWS electrode classification code, so the label already tells you the coating and current.
E6010 carries a cellulosic sodium coating and burns only on DCEP (electrode positive). The cellulose creates a forceful, high-pressure arc that blasts through mill scale, rust, oil, and paint, delivering deep penetration and a thin, flaky slag. That digging action is why it dominates pipeline root passes and open-root joints, where the arc has to keyhole the gap. The trade-off is a harsh arc, heavy spatter, and a demand for DC and a steady hand.
Swap the sodium in that coating for potassium and you get E6011. The cellulose/potassium blend ionizes more easily, so the rod restarts and runs on AC as well as DCEP while keeping 6010’s deep penetration and dirt tolerance. That makes it the go-to repair rod for rusty gates, trailers, and farm equipment. If your machine is AC-only, reach for 6011 instead of 6010 — every single time.
E6012 uses a rutile-sodium coating that builds wide, flat beads under a fast-freezing slag. This “fill-freeze” behavior is handy for bridging gaps and vertical-down work, though its shallow penetration means slow travel can leave cold lap — a common cause behind an overlap defect.
E6013 is the rod most beginners learn on. Its high-titania (rutile) potassium coating runs on AC, DCEP, or DCEN and produces a soft, forgiving arc with shallow penetration, easy restarts, and a smooth bead under a slag that practically peels off. It is superb on clean sheet metal and light fabrication. It is not a structural rod, though: shallow fusion makes 6013 a poor choice for code work.
| Rod | Coating | Polarity | Penetration | Slag & Spatter | Best Use |
|---|---|---|---|---|---|
| E6010 | Cellulosic sodium | DCEP only | Deepest, digging | Thin slag, heavy spatter | Pipeline roots, dirty steel |
| E6011 | Cellulosic potassium | AC or DCEP | Deep, digging | Thin slag, heavy spatter | Repairs, AC machines, rusty metal |
| E6012 | Rutile sodium | AC or DC | Shallow–medium | Thick fast-freeze slag | Gap bridging, vertical-down |
| E6013 | Rutile potassium | AC, DCEP, DCEN | Shallow | Heavy, easy-peel slag, low spatter | Sheet metal, beginners, light fab |
| Rod | 3/32 in (2.4 mm) | 1/8 in (3.2 mm) | 5/32 in (4.0 mm) |
|---|---|---|---|
| E6010 | 40–85 A | 75–125 A | 110–170 A |
| E6011 | 40–85 A | 75–125 A | 110–170 A |
| E6013 | 40–90 A | 80–130 A | 120–180 A |
| E7018 | 70–110 A | 110–165 A | 140–210 A |
These are typical smooth-running ranges for flat and horizontal work; always verify against the manufacturer’s data sheet. Notice how E7018 runs hotter at the same diameter.
The pattern is simple. The more cellulosic the coating, the deeper it digs and the dirtier the steel it tolerates — but the rougher the finish. Rutile rods trade penetration for a smooth arc and a self-peeling slag. That’s why 6010 and 6011 live on pipelines and repairs, while 6013 lives on sheet metal and light fabrication. Current follows the same logic: cellulosic rods are DC-centric, and rutile rods are flexible across AC and both DC polarities. Low-hydrogen rods, by contrast, demand clean, dry metal.
Here’s the rule that saves the most frustration: on an AC-only machine, treat E6011 as your 6010. It behaves almost identically on dirty steel but actually starts. A 6010 won’t run on AC at all. When you step up from 6013 to structural work, the natural next move is a low-hydrogen rod like E7018, which needs clean metal and the right amperage and polarity. Get those dialed in with our guide to 3/16 E7018 amperage, settings, and technique before you switch.
Quick Note: The last digit of an electrode like E6013 once described welding position, but the “3” is no longer used as a position designator because those electrodes are obsolete. Today 6013 simply means a rutile rod — it tells you nothing about position.
If you weld thick plate, high-strength steel, or anything that will be inspected, the low-hydrogen family is where you live. Hydrogen is the enemy here. Moisture in a coating breaks down in the arc and dumps hydrogen into the molten weld pool. As the weld cools and the steel hardens, that trapped hydrogen can’t escape, and it builds pressure until the metal cracks—sometimes hours after you’ve walked away. Low-hydrogen electrodes are engineered to keep that hydrogen out.
They do it with a lime-based (basic) coating that carries very little moisture and resists reabsorbing it. That’s why they’re called “low-hydrogen,” and it’s why they dominate structural welding.
E7018 is the rod most engineers, inspectors, and building codes reach for. It’s specified by AWS D1.1 and most structural codes, and the “8” tells you it’s a low-hydrogen potassium coating with iron powder. That iron powder boosts deposition and lets the rod run on AC or DCEP. Expect smooth, medium penetration, decent out-of-position capability, and welds that are tough and ductile. For thicker material, check your 3/16 E7018 amperage settings carefully, since low-hydrogen rods are less forgiving of a cold, fast arc than rutile rods.
Strip away the iron powder and you get two close cousins. E7015 carries a low-hydrogen sodium coating and runs on DCEP only. E7016 uses a low-hydrogen potassium coating that adds arc stabilizers, so it runs on AC or DCEP. Both are all-position, both are low-hydrogen, and both produce quality similar to E7018—just with a bit less deposition. Choose E7016 when you only have AC power available, E7015 when you’re on DC and want maximum arc stability. See how current choice changes everything in this guide to DCEN vs DCEP polarity.
E7024 is a “jet rod” loaded with iron powder and a rutile-based coating. Its deposition rate is enormous—often two to three times that of E7018—but you pay for it with position. E7024 is usable only in flat and horizontal fillet positions, where gravity helps you lay down metal fast. It’s a favorite for heavy fillet welds on structural steel. E7028 is the low-hydrogen, AC-capable counterpart, giving you similar high deposition with the hydrogen protection of a basic coating, again limited to flat and horizontal fillets.
Quick Note: Low-hydrogen coatings behave like a sponge for moisture once exposed to air. Store opened rods in a holding oven at 250–300 °F (120–150 °C), and don’t leave them lying on the bench overnight.
Because low-hydrogen rods actively absorb atmospheric moisture, storage is not optional—it’s part of the process. A properly planned welding shop includes a holding oven. After opening, keep rods at 250–300 °F (120–150 °C). If they’ve been exposed for a while, re-dry them per the manufacturer’s schedule—commonly around 500–800 °F (260–430 °C) for an hour or more, depending on the electrode and coating.
Codes back this up. AWS D1.1 requires low-hydrogen electrodes rated H8 or better for many structural applications, meaning a maximum of 8 mL of diffusible hydrogen per 100 g of weld metal. That standard exists precisely because hydrogen cracking is a real, documented failure mode. You can read the manufacturer details at Lincoln Electric’s AWS classification guide, and Hobart Brothers keeps a matching reference. There’s also a reason low-hydrogen rods demand clean, dry base metal: any rust, oil, paint, or moisture reintroduces the hydrogen you’re trying to keep out.
Cellulosic rods like E6010 and E6011 are the opposite philosophy. Their coating is high in cellulose, which generates a forceful, deep-penetrating arc ideal for pipe roots and dirty, rusty steel. But they add hydrogen to the weld, so they’re a poor match for thick sections and high-strength steel where cracking risk is highest. Low-hydrogen rods trade some of that digging power for strength and crack resistance—which is exactly why structural work lives and dies by E7018.
The AWS digits tell you a rod’s strength, position, and coating type on paper. The flux coating itself is what you actually feel at the stinger. It controls how the arc starts, how it digs, how much spatter flies, how the slag releases, and how much hydrogen ends up in the weld. Nearly every carbon steel electrode falls into one of three coating families: cellulosic, rutile (titania), and basic (low-hydrogen). That’s why two rods with identical tensile numbers can feel like completely different tools. Knowing them turns guesswork into deliberate selection.
Cellulose in the coating burns off as gas, producing a violent, forcefully digging arc with deep penetration. The resulting slag is thin and freezes fast, which is exactly why cellulosic rods like E6010 and E6011 shine on root passes and vertical-up work where you need the puddle to set quickly. That aggressiveness has a cost: cellulosic rods deposit more hydrogen than the other families. The thin slag means less cleaning between passes, but the deep dig can blow through thin sheet if you aren’t careful.
Rutile coatings give a soft, quiet arc that strikes easily and runs with low spatter. Penetration is shallow to medium, and the slag is glassy and largely self-releasing, so cleanup is quick. E6012 and E6013 are the classic rutile rods, and their forgiving nature makes them a favorite for sheet metal, general fabrication, and beginners learning to run a bead. Because the arc is so gentle, rutile rods also tolerate rusty or dirty steel better than the rest.
Basic coatings use a lime-fluoride chemistry that does the heavy lifting on quality. They produce very low diffusible hydrogen, which sharply reduces the risk of underbead cracking, and they deliver high ductility plus good low-temperature notch toughness. That is why E7018 and similar low-hydrogen rods are specified for structural and code work. If you want to dial one in, our guide to E7018 amperage settings walks through the numbers. The trade-off is a slightly stiffer arc, a slag that is harder to remove, and the need to keep these rods dry, since moisture destroys the low-hydrogen benefit.
Polarity is not a matter of welder preference. It’s dictated by the flux chemistry, and the electrode classification system ties each coating to its required current. Cellulosic E6010 requires DCEP (electrode positive) to run correctly, while rutile E6013 happily runs on AC or DC either polarity. Basic rods vary too, so always check the data sheet. For a deeper breakdown of current direction, see DCEN vs DCEP polarity.
Electrodes are also grouped by freeze rate. Fast-freeze electrodes solidify quickly, which is what you want when welding vertically or overhead. Fill-freeze electrodes stay fluid longer to fill gaps and flatten beads. A third group, fast-fill, deposits metal quickly for flat and horizontal work, the opposite of what you want out of position. Per the AWS classification guidance, E6010 is a fast-freeze electrode and E6013 is a fill-freeze electrode, a distinction that predicts which positions each one handles.
Quick Note: Coating families aren’t interchangeable in service. A rutile rod that welds beautifully today can crack later in high-restraint, low-temperature joints where a basic low-hydrogen rod would have held. Match the coating to the service condition, not just to how easy the arc feels.
Penetration profile and joint type follow directly from all this. Deep-digging cellulosic rods suit open roots and thick plate; shallow rutile rods favor thin material and fit-up you can’t guarantee; basic rods give medium penetration with the cleanliness structural codes demand. Switching families is often an easy field fix, but it changes the metallurgy too, so make the call deliberately.
Once you leave plain carbon steel behind, electrode selection stops being about which rod runs smoothest and starts being about metallurgy. Specialty rods are engineered to match a specific base metal, defeat a specific failure mode, or handle a job that no general-purpose electrode can touch. Here are the four families you will meet most often, and each one has a narrow job where it shines.
AWS A5.4 governs stainless steel covered electrodes, and the grade stamped on the box tells you both the alloy and the coating. Choosing a stainless rod comes down to matching the deposit to the base metal, so the weld keeps roughly the same chromium and nickel balance as the parent. Three grades cover the vast majority of shop work:
The “-16” suffix signals a rutile coating that runs on AC or DCEP and lays a smooth, easily cleaned bead. Match the electrode to the base metal first, then confirm the coating suits your power source. Never grab a carbon steel rod for stainless just because it is what is on the shelf; the deposit will rust and fail.
Quick Note: Stainless and other high-chromium consumables release hexavalent chromium fume, a confirmed carcinogen. OSHA limits exposure, so local fume extraction and a proper respirator are not optional. Plan your ventilation before you strike an arc by following this guide to setting up a safe welding shop.
AWS A5.5 covers low-alloy steel electrodes made for work that must survive heat, pressure, or both. E8018-B2 is a chromium-molybdenum rod for elevated-temperature service such as steam piping and pressure vessels. E7018-A1 is a carbon-molybdenum electrode used where creep strength matters. These alloys harden quickly and crack easily when cooled too fast, so preheat and interpass temperature control are part of the job, not a suggestion. A preheat in the 200–400°F range is typical, and a slow, controlled cool-down prevents the hard, crack-prone structure that forms when the weld chills too quickly. If you have ever fought post-weld cracking, the same discipline described in this guide to welding hardened steel applies here.
Cast iron is a different animal, and AWS A5.15 governs its electrodes. The two you will see are ENi-CI, a nearly pure nickel rod, and ENiFe-CI, a nickel-iron version that is stronger and more economical. Both are chosen because they minimize cracking in a brittle base metal that cannot stretch to absorb weld shrinkage. The nickel deposit also stays ductile and machines cleanly, which matters when a repaired casting has to be re-drilled.
Technique matters as much as the rod. Lay short stringer beads, let each one cool before starting the next, keep the heat low, and peen each bead while it is still warm to relieve stress. A tight arc and a narrow bead keep heat input to a minimum.
Aluminum can be welded with SMAW electrodes, and they earn their keep for quick repairs when no TIG or MIG machine is nearby. In practice, though, TIG and MIG dominate aluminum work. The oxide layer on aluminum melts at a far higher temperature than the metal beneath it, and aluminum pulls heat away so fast that holding a stable stick arc becomes a constant fight. When you do run aluminum stick, many operators adjust polarity to improve the cleaning action, the same thinking behind DC welding aluminium. For anything structural or cosmetic, reach for a spool instead and pick a filler from this guide to MIG welding wires.
Walk into any weld shop and you’ll hear it: “hand me a MIG rod.” Even though MIG and flux-cored wires aren’t rods at all in the strict sense, the label sticks because they do the exact same job as a stick electrode. They carry filler metal into the joint, they’re classified under the same AWS letters-and-numbers logic, and they even share a designation family. The only real difference is delivery. Stick electrodes are coated cut lengths that burn down; wire electrodes are bare or flux-filled strands pulled continuously off a spool.
Stick electrodes start with a single E, which stands for electrode. Solid wires often start with ER, and that extra letter is the giveaway: it means the filler can be used as either an electrode or a rod. That’s why the same spool of ER70S-6 can feed a MIG gun as an electrode or be snipped into lengths for TIG work as a filler rod.
Take ER70S-6 apart and it reads cleanly. The ER is the dual-use filler classification. 70 is the minimum tensile strength in thousands of psi (70,000 psi). The S marks it as a solid wire. The 6 is the chemistry suffix, and here’s where it earns its reputation. Compared to ER70S-3, ER70S-6 carries higher silicon and manganese, which act as deoxidisers. Those elements scavenge oxygen and help the puddle stay clean, so the wire tolerates rusty or dirty steel better. That’s exactly why it’s the most popular general-purpose MIG wire on the market. ER70S-3 is the leaner cousin with less silicon and manganese; it runs beautifully on new, well-prepped steel but forgives less mill scale and rust. To see the full chemistry breakdown, read What Is MIG Welding Wire Made Of? Composition Explained. For a wider size range and selection tips, our MIG Welding Wires: Types, Sizes & Selection Guide covers them all.
Flux-cored wires drop the “R” and go back to a plain E, because the wire itself is the electrode in the arc. Under the AWS system (Hobart Brothers keeps a solid breakdown), E71T-1 and E71T-11 both indicate 70,000 psi minimum tensile strength, with the T flagging a tubular flux core.
The shielding difference matters. Solid MIG wire always needs an external gas bottle, but flux-cored electrodes can go either way. If you’re still sorting that out, Is Flux Core the Same as MIG? Differences Explained walks through it, and Polarity for Flux Core Welding: DCEN vs DCEP explains why the polarity setting changes between the two styles.
Quick Note: Dialing in a wire welder for the first time? Our How to Use a Wire Welder guide covers setup, gas, and travel speed.
Stick welding stops every few inches to swap a new electrode; wire welding doesn’t. One continuous strand feeds through a gun and keeps the arc lit for the whole bead, which is a big part of why MIG and flux-cored are so productive. Solid wire is sized by diameter (0.030 in, 0.035 in, and up) rather than by a coated cut length, and it arrives on spools ready to feed.
Filler metals for these processes fall under two AWS specs. AWS A5.18 covers carbon steel electrodes and rods for gas-shielded arc welding — GMAW, GTAW, and plasma arc welding — which is where ER70S-3 and ER70S-6 live. AWS A5.20 covers carbon steel electrodes for flux-cored arc welding, home to E71T-1 and E71T-11. Both specs follow the same strength-and-chemistry pattern, so once you can read one box, you can read them all.
Choosing an electrode gets easy once you stop guessing and work through four filters in order: strength and chemistry, position, current, and coating. Run your job through these and the rack shrinks to one or two boxes.
The first two digits of the classification tell you tensile strength in thousands of psi. For the most common structural steel on earth, A36, this is straightforward: A36 carries a 36 ksi yield and 58–80 ksi tensile, so an E70XX rod (70 ksi minimum tensile) matches it with a comfortable margin. 60 ksi rods also work on thinner A36 sections, but E70XX is the safe, industry-standard match.
Step up only when the steel demands it. For higher-strength grades, you move to E80XX or E90XX electrodes classified under AWS A5.5. For alloy, stainless, or hardenable steels, chemistry matters as much as strength. A quick reference on welding hardened steel shows why preheat and a matched alloy filler often matter more than raw tensile numbers. If you’re feeding wire instead of stick, the same logic applies to MIG welding wires and their classifications.
The last digit of the code tells you which positions the rod can handle. All-position rods run 1 (all positions), while 2 means flat and horizontal only. For vertical-up welding, E7018 and E6010 are the standards — they freeze fast enough to hold a bead without dripping. Overhead work typically uses E7018 at reduced amperage so the puddle doesn’t sag. E7024 deposits metal far faster than any all-position rod, but only in flat and horizontal fillets. Match the position to the joint, and you’ll avoid the uphill battle of forcing a flat-only rod into vertical work.
Check what your machine can deliver. An AC-only buzz box runs only AC-rated rods: E6011, E6013, E7018, and E7024. It cannot run the DCEP-only E6010. If you’re running wire, polarity rules change: see DCEN vs DCEP for flux core for how direction affects penetration and bead shape.
Quick Note: Always confirm your machine’s duty cycle and available polarity before buying a box. An electrode that needs DCEP is useless on an AC-only machine, no matter how good the deal.
Rutile coatings (E6013) tolerate rusty, dirty steel and strike easily, making them the forgiving choice for repairs. Basic low-hydrogen coatings (E7018) resist moisture pickup and deliver lower hydrogen, so they’re required where cracking risk is high or where the AWS classification demands it. When base metal is dirty or fit-up is poor, favor cellulosic and rutile rods; when strength and crack resistance matter, favor basic.
| Rod | Strength | Positions | Current | Best For |
|---|---|---|---|---|
| E6010 | 60 ksi | All | DCEP only | Pipe roots, deep penetration |
| E6011 | 60 ksi | All | AC/DCEP | Dirty steel, AC machines |
| E6013 | 60 ksi | All | AC/DC | Sheet metal, light repair |
| E7018 | 70 ksi | All | AC/DCEP | Structural, low-hydrogen work |
| E7024 | 70 ksi | Flat/Horiz. | AC/DC | High-deposition fillets |
An electrode that is too weak for the joint is the obvious failure, but over-matching creates its own problems. A rod far stronger than the base metal can produce a weld that refuses to yield with the parent steel, concentrating stress and inviting cracking at the toe. On A36, reaching for E100XX “just to be safe” is usually a mistake — the heat-affected zone becomes the weak link. Match, don’t overshoot.
For code work governed by AWS D1.1, matching the filler to the welding procedure specification (WPS) is mandatory. The WPS already solved these four questions for you. Deviate from it and your weld is out of compliance, regardless of how pretty it looks. Confirm code requirements and fume limits via OSHA’s welding guidance before you commit to a filler.
Work the four filters in order — strength, position, current, coating — and the choice becomes mechanical. When in doubt, the WPS wins.
Most stick welds fail for boring reasons: the wrong rod in the stinger, or the right rod stored wrong. Knowing the classic errors before you strike an arc saves a lot of grinding and rework. None of these problems are exotic, and almost every one traces back to a decision made before the first spark.
Catch these five early and you sidestep most of the frustration people blame on technique.
| Symptom | Likely cause | Fix |
|---|---|---|
| Porosity | Damp rods, arc too long, dirty base metal | Re-dry rods, tighten arc, grind to bare metal |
| Excess spatter | Long arc, amperage too high | Shorten arc, reduce amps |
| Slag inclusions | No cleaning between passes, wrong angle | Chip each pass, adjust travel angle |
| Hard restarts | Cold 7018 tip, heavy slag cap | Tap to break slag, restart on scrap first |
Slag that gets trapped instead of removed becomes a defect, not a fix. Chip and brush between every pass; a wire brush alone rarely clears the heavy slag left by a 7018 cap. If you see overlap along a bead edge, that’s a separate problem worth reading up on in our breakdown of the overlap welding defect: causes, detection and repair. On the wire-fed side, judging beads by eye is a skill in itself — see good and bad MIG welds for what a healthy bead should look like.
Cellulosic and rutile rods (6010, 6011, 6013) tolerate a normal dry shop. Low-hydrogen rods do not. Keep 7018 and its relatives in a heated rod oven, or sealed in their original packaging until use. If they’ve been exposed, re-dry them per the manufacturer’s schedule — often one hour at roughly 250–300°F for a light pickup. This is a moisture-management habit, not a formality: Lincoln Electric notes that proper storage is central to the low-hydrogen benefit.
A sealed quiver only works while it stays sealed; every time you pull a rod and leave the cap off, you undo the benefit. Keep a small working supply in a portable oven near the machine and refill it from the main stock.
Quick Note: A rod oven without a working thermometer is just a warm cabinet. Verify temperature or you may be baking in moisture rather than driving it out.
Hold a short arc and a steady drag angle of about 10–15° for most electrodes. Arc length matters most with E7018: run it long and you let atmospheric hydrogen and nitrogen into the puddle, defeating the low-hydrogen chemistry you paid for. A tight arc also stabilizes the arc and cuts spatter. Long arcing is the easiest way to wreck an otherwise sound weld, so build the habit early. Keep a dry, well-planned shop with rod storage near the machine, and you’ll reach for dry rods by default.
Every electrode you strike an arc with does more than lay metal. It burns its coating, melts its core, and throws a fine cloud of metal oxides into the air you breathe. The rod you choose quietly decides what ends up in that cloud. So choosing wisely is about more than weld quality; it is about what your lungs absorb over a career.
Mild steel rods produce fume rich in iron and manganese. Stainless electrodes add chromium and nickel, and in the heat of the arc that chromium forms hexavalent chromium, or Cr(VI), a known carcinogen. According to OSHA, an estimated 558,000 U.S. workers are exposed to Cr(VI) fume, and welding is among the trades with the largest numbers of exposed workers.
Manganese deserves just as much respect. Prolonged exposure to manganese fume can cause Parkinson’s-like symptoms, including tremors, slowed movement, and mood changes. OSHA’s ceiling limit for manganese fume is 5 mg/m3, a figure worth remembering before you weld in a closed garage. Acute fume exposure can also cause eye, nose, and throat irritation, dizziness, and nausea, while prolonged exposure may cause lung and other cancers.
Metal fume fever is the short-term visitor many welders meet first. It feels like the flu: chills, fever, aching muscles, and a metallic taste, usually after welding galvanized or zinc-coated steel. It fades in a day or two, but it is your body telling you that your ventilation was not good enough.
NIOSH recommends limiting airborne exposure to all Cr(VI) compounds to 0.2 µg/m3 as an 8-hour time-weighted average, and it considers every Cr(VI) compound an occupational carcinogen. That recommended limit is 25 times stricter than OSHA’s enforceable PEL, a gap that tells you how seriously the research community views welding fume.
Here are the numbers that matter when you are selecting a rod and setting up a station.
| Contaminant | Key limit | Notes |
|---|---|---|
| Hexavalent chromium, Cr(VI) | OSHA PEL 5 µg/m3 (8-hour TWA) | NIOSH REL 0.2 µg/m3; NIOSH treats all Cr(VI) compounds as occupational carcinogens |
| Manganese fume | OSHA ceiling 5 mg/m3 | Linked to Parkinson’s-like symptoms |
| Welding fume (total) | Evaluated per component | Engineering controls come first, respirators second |
OSHA requires engineering and work practice controls, such as local exhaust ventilation, to reduce exposures to or below the PEL, supplemented by respiratory protection when needed. In practice that means capturing fume right at the arc with a fume extractor or a well-placed hood, rather than just propping a door open. For short jobs, a properly fitted respirator with P100 filters can cut particulate exposure significantly; in confined spaces or on stainless, supplied-air systems are the safer choice.
For personal protection, pair an auto-darkening helmet with quality protective eyewear for welding. Add leather gloves, a welding jacket, and hearing protection. Some welders face extra risk; our guide on welding while pregnant covers what changes. If you work in a small shop, plan your layout so fumes move away from the breathing zone, and our guide to setting up a safe shop explains airflow and station placement.
Quick Note: If you can smell or taste metal after a weld, your ventilation is not doing its job. Step up extraction and respiratory protection before you strike another arc.
After all the codes and chemistry, the practical answer is refreshingly simple.
That approach keeps you learning without burning money on rods you do not need, while keeping low-hydrogen electrodes ready for the jobs that demand them. Read the code, match the rod to the work, and control the fume. Start simple, layer in specialty electrodes as your work grows, and treat ventilation as part of the process rather than an afterthought. Do that, and you will choose the right electrode for the long haul.
E7018 is the most widely used electrode for structural and general fabrication because it produces 70,000 psi welds with a low-hydrogen coating that resists cracking. E6013 is the most common rod for beginners and light sheet-metal work because it is forgiving and easy to strike.
Take E7018: E means electrode, 70 is the minimum tensile strength in ksi (70,000 psi), 1 means it can be used in all positions, and 8 identifies the low-hydrogen iron-powder coating and its current requirements. Reading these digits lets you predict strength, position capability, and polarity before you strike an arc.
No. E6010 has a cellulosic sodium coating that requires DCEP (electrode positive DC) and will not run stably on AC. If you only have an AC machine, use E6011, which is the AC-capable version of the same deep-penetrating electrode.
E6013 is the classic beginner rod. Its rutile coating gives a soft, easy-to-strike arc, minimal spatter, and self-releasing slag, and it runs on AC or DC in either polarity. For learning structural welding, E7018 is the next step but demands clean metal and proper storage.
E6013 is a 60,000 psi rutile electrode with shallow penetration, ideal for thin, clean metal and light fabrication. E7018 is a 70,000 psi low-hydrogen electrode with medium penetration that is the standard for structural and pressure work where strength, ductility, and crack resistance matter.
Solid bare wires and most cellulosic and rutile stick electrodes have long shelf lives if kept dry. Low-hydrogen electrodes like E7018 are the exception: their coatings absorb moisture, so they must be stored in a holding oven and re-dried per the manufacturer’s instructions to prevent porosity and hydrogen cracking.
A welding rod is typically a coated cut-length stick electrode that carries the welding current, as in SMAW stick welding. A welding wire is a continuous filler fed from a spool, such as MIG or flux-cored wire, and may or may not be the current-carrying electrode.
Yes. E7018 deposits weld metal with a minimum tensile strength of 70,000 psi, while E6013 is rated at 60,000 psi. Beyond strength, E7018 offers better ductility and low-temperature toughness, which is why it is preferred for structural and code-governed work.
Match the electrode to the base alloy using AWS A5.4 grades: E308L-16 for 304 stainless, E316L-16 for molybdenum-bearing grades like 316, and E309L-16 for joining stainless to carbon steel. Always control hexavalent chromium fume with ventilation and respiratory protection.
E7018 needs a short, tight arc; a long arc destabilizes the low-hydrogen arc and lets contamination into the puddle. Sticking at the start is often caused by low amperage, a damp coating, or a dirty workpiece, so check the manufacturer’s amperage range and keep the rod dry and the metal clean.