3/32 E7018 Amperage: Settings, Polarity & How to Run It
My first E7018 rod went about as badly as a weld can go without catching fire. I was…
READ ARTICLE →You’re standing in the supply aisle holding two nearly identical rods. One reads E6013, the other E7018, and the price tag says the wrong pick will leave you grinding out a cracked, porous bead. Those little numbers aren’t random — they’re a complete instruction manual printed right on the electrode, and once you can read them, choosing the right rod becomes almost automatic.
This is exactly why understanding the electrode number meaning is one of the first skills every welder should master. Whether you’re laying your first bead during your welding practice or working on a code-critical structural job, the alphanumeric code on a stick electrode tells you how it will perform before you strike an arc. For carbon steel shielded metal arc welding (SMAW), these classifications are standardized and governed by the American Welding Society (AWS).
The AWS classification system was first issued over 80 years ago for carbon steel covered electrodes (AWS A5.1). Since then, it has evolved with industry needs, with AWS A5.1-2012 and the current A5.1/A5.1M:2025 governing carbon steel SMAW electrode classification. This standardization is what allows a welder in any shop to trust that an E7018 from one manufacturer will meet the same minimum requirements as one from another. As explained by Lincoln Electric, these codes exist to remove guesswork and promote safety and code compliance.
Quick Note: Code compliance isn’t just paperwork. Many structural, pressure vessel, and bridge jobs require traceable electrodes that meet an AWS specification to pass inspection.
Take the industry staple, E7018, which is often called the ‘workhorse’ of the stick welding industry. At first glance, it looks cryptic, but each character serves a purpose. Here’s what a typical SMAW code like E7018 encodes:
Choosing the correct polarity based on this digit is just as important as strength. For example, understanding polarity for flux core welding or SMAW current requirements can prevent lack of fusion, excessive spatter, and poor penetration. Resources like Open Washington’s welding textbook and Clause 5 break these rules down in further detail.
Decoding these numbers has real consequences for your welds, your wallet, and your safety. First, code compliance often hinges on using the correct classified electrode. Second, matching base metal strength prevents a weak weld from failing under load. Third, selecting a low-hydrogen electrode and proper storage helps with avoiding hydrogen cracking, a common defect in structural work. Fourth, choosing polarity correctly optimizes heat input for your setup. Lastly, the right rod gives you the arc characteristics needed to work in tight spaces or awkward positions.
Short Note: These benefits extend far beyond stick. The same logic carries over to flux-cored wires and solid wires, which follow their own AWS classifications, such as those found in AWS A5.20. If you’re transitioning to wire processes, check out our guides on flux core vs MIG or how to use a wire welder.
As we move through this guide, we’ll dissect each digit, explore suffixes, compare processes, and cover common pitfalls. By the end, that glance at the rod in your hand will tell you everything you need to know — no guesswork required.
Every stick electrode sold in North America carries a classification stamped on the flux or printed on the box, and that string is not decoration — it is a specification. The American Welding Society built this system so a welder can glance at a rod and know its tensile strength, welding position, coating type, and current before striking an arc. Once you see the code as a set of slots instead of a random number, it sticks for good.
The classic example is E7018, so we will use it to walk the whole string. E6010 gets the same treatment, because comparing the two makes the logic click.
The leading “E” simply means electrode — a filler metal that carries the welding current. In stick welding (SMAW), the rod is both conductor and filler, which is why the prefix matters. Switch to a wire process and the letters change: “ER” signals a metal that can serve as either electrode or rod, while a bare “R” marks a rod that does not conduct current. For now, remember that E means current passes through the metal as it is consumed. The AWS classification rules lay this out for the whole family of filler metals.
The first two digits of a four-digit code give the minimum tensile strength of the deposited weld in thousands of pounds per square inch, or ksi. E7018 points to 70 ksi; E6010 points to 60 ksi. When the classification carries five digits, the first three hold the strength, so E11018 lands at 110 ksi. Those numbers come from as-welded test specimens pulled per the governing specification, which is why the figure is dependable rather than marketing.
The digit right after the strength figures tells you which positions the rod is approved to fill. A “1” means all positions: flat, horizontal, vertical, and overhead. A “2” means flat and horizontal fillet only, which is why you will never see an E7024 run overhead. Position approval is about the slag system, not sales copy — fast-freezing and rutile coatings hold vertical and overhead puddle weight far better than iron-powder coatings that want to be flat.
The final digit encodes the flux coating and, through it, the recommended current and polarity. E7018’s “8” is a low-hydrogen, iron-powder coating built for AC or DCEP and the smooth, strong beads demanded on structural steel. E6010’s “0” is high-cellulose sodium — a DCEP-only coating that produces deep, digging penetration and a forceful arc. That single digit changes how the rod behaves, which is why settings and technique follow directly from it; the E7018 amperage, polarity, and technique guide shows how the coating digit drives real machine settings.
| Position in code | E7018 | E6010 | What it means |
|---|---|---|---|
| Prefix | E | E | Electrode — carries current |
| Strength digits | 70 | 60 | 70,000 / 60,000 psi minimum tensile |
| Position digit | 1 | 1 | All positions |
| Coating / current digit | 8 | 0 | Low-hydrogen iron powder / high-cellulose sodium |
After the core characters you may find a suffix, and here the governing spec often changes. AWS A5.1 covers carbon steel SMAW electrodes like E6010, E6011, E6013, E7014, E7018, and E7024. AWS A5.5 takes over for low-alloy rod: E7018-A1, E8018-C3, and E9018-G carry alloy designators that pin down chemistry. An “H” plus a number (H4, H8) limits diffusible hydrogen, which matters on crack-sensitive steel. An “R” flags a moisture-resistant coating, and “-1” marks a specific variant defined inside the specification.
The format is flexible in one place only: how many digits represent strength. A four-digit classification is E + two strength digits + one position digit + one coating digit. A five-digit classification is E + three strength digits + one position digit + one coating digit. So E6010 breaks down as E-60-1-0, and E11018 as E-110-1-8. Every other character keeps the same job, which is why learning one code teaches you all of them.
Quick Note: Lowercase letters and hyphens are not typos. Specifications define exactly how a classification is written — E7018-A1 keeps its hyphen, while some suffixes are squeezed together. Always copy the code straight from the spec or the manufacturer’s data sheet.
When you read or write a Welding Procedure Specification, the electrode line names the exact classification — “E7018, 1/8 in., DCEP” is a complete instruction, not a suggestion. The code tells the procedure writer the strength, position, and polarity, and it tells the welder whether the rod in hand actually matches the paper. Get the digits wrong on a critical joint and you risk a cracked or understrength weld, which is why welding practice starts with reading labels. The individual slots deserve a closer look next.
Once you strip away the leading “E,” the first two digits are the part most welders recognize instantly — and the part they most often misread. Those numbers tell you the minimum tensile strength of the deposited weld metal, measured in thousands of pounds per square inch (psi). So an E6010 indicates a minimum tensile strength of 60,000 psi, and an E7018 indicates 70,000 psi. An E10018 designates a 100,000 psi electrode; an E11018, 110,000 psi.
That single number governs one of the most consequential decisions in a weld: whether your filler metal can hold the loads the base metal carries.
Tensile strength is the stress at which the weld metal fractures when pulled apart. It is not the same as yield strength, which is the stress at which the metal begins to deform permanently. A rod can meet its tensile requirement while still having a lower yield point, and those two properties matter differently depending on the job. For most structural work, engineers care about both, but the AWS classification code leads with tensile strength because it’s the benchmark that lets you compare consumables at a glance.
There’s a subtlety that trips up even experienced hands: the number on the box is a nominal class, not the exact test value. In the AWS A5.1 tables, 60-class electrodes are commonly specified at a 62 ksi minimum tensile and 70-class at a 72 ksi minimum. That headroom exists because the specification sets an actual acceptance floor above the round class number. Always consult the AWS A5.1/A5.1M specification rather than assuming the headline number is the exact requirement.
Quick Note: The class number is a floor, not a target. A “70” rod must test at or above 72 ksi minimum in A5.1 — the extra 2 ksi is the specification’s built-in safety margin.
Why does the tensile digit matter so much? Because structural codes tie filler metal selection to the strength of the steel you’re welding. AWS D1.1 Table 5.7 maps base metal groups to compatible filler metal groups, generally requiring that you match or overmatch the base metal’s minimum specified tensile strength.
Undermatching — using a weaker filler on stronger steel — is the classic mistake. Weld 70 ksi steel with a 60-class rod and the weld becomes the weak link, the first place a structure yields under load. Overmatching is usually the safer default, which is why an E7018 is the workhorse for A36 and grade 50 steels alike.
But overmatching is not a free pass. Push too far on high-strength steel and you introduce hydrogen cracking, reduced ductility, and mismatch between the weld’s stiffness and the base metal’s behavior. That’s why high-strength rod selection should also factor in hydrogen control and preheat — covered in our guide to welding hardened steel. A 110 ksi electrode does you no favors if the heat-affected zone cracks the moment the part cools.
Beyond the common 60 and 70 classes, manufacturers produce low-hydrogen electrodes in 80, 90, 100, 110, and even 120 ksi families, often with alloy suffixes that add chromium, molybdenum, or nickel for toughness and corrosion resistance. These are specialty consumables, and the strength number is your first filter, not your only one.
When dialing in heat and polarity to get the most from a rod — whether a 70-class workhorse or a 100-class alloy — the polarity your machine runs matters as much as the code. Our breakdown of TIG welding polarity explains how electrode-positive versus electrode-negative behavior governs penetration and bead profile across processes, worth reviewing before you assume any rod performs the same on every setting.
Get the tensile digit right and you’ve cleared the biggest hurdle in electrode selection. Practice these habits deliberately and your results improve fast — the same discipline that separates students from professionals in our complete guide to building real welding skills.
When scanning an AWS stick electrode code, the third digit is one of the most practical indicators for your job. Found in the middle of the four-digit sequence (such as the “1” in E7018), this single number tells you which welding positions the electrode is designed to perform in safely and effectively. Choosing the correct position rating can be the difference between a sound root pass and a pile of grinding dust.
While electrode classifications have evolved over the years, three position digits are still referenced today. Each one directly correlates to the way molten metal and slag behave against gravity:
Quick Note: The number 3 is no longer used for position because those electrodes are obsolete. Modern AWS classifications have phased out the “3” rating, so you will not see it on current production electrodes.
Welding position isn’t a suggestion, but a limitation of physics. To fully understand these ratings, it’s important to look at the forces acting on your puddle. For those looking to strengthen their fundamentals, resources like Welding Practice: The Complete Guide to Building Real Welding Skills can help build the muscle memory needed for out-of-position work.
Four factors dictate whether a rod can weld out of position:
There is one extremely important exception to be aware of: the “all position” rating for E7018 has a size caveat. Industry standards, as outlined by the Lincoln Electric AWS classification guide and the AWS A5.1 specification, note that E7018 is typically limited to electrodes 5/32 in / 4.0 mm and under for vertical and overhead welding. Larger diameters drastically increase puddle size, making them impractical to control against gravity.
Note: When working in tight quarters or on structural pipe, always verify diameter limitations before assuming an “all-position” rod is viable for your pass. This small check pairs perfectly with a safe shop layout, such as those detailed in Welding Facilities: How to Plan & Set Up a Safe Shop.
In short, the third digit is your positional blueprint. Whether you’re running an E6010 all-position for pipe roots or an E7024 flat/horizontal for high deposition, understanding this number allows you to match your electrode to physics, not guesswork. With this knowledge in tow, you’re ready to move onto the final digit of the code: the coating, current, and penetration characteristics.
Now that we’ve broken down the first three digits of the AWS electrode code, it’s time for the master key: the last digit. This single number determines the electrode’s coating type, recommended welding current and polarity, arc behavior, penetration, slag characteristics, and moisture sensitivity. Whether you’re running an AC or DC machine, this digit will tell you exactly how your rod will perform. Let’s break down codes 0 through 9 to help you dial in your next bead.
The first two coating classifications are known for their brute force and deep penetration. These are the go-to rods for jobs that require you to burn through rust, mill scale, or paint.
Quick Note: E6010 and E6011 behave like siblings due to their cellulosic flux. The only major difference is arc stability on AC, with E6011 being far more forgiving for those utilizing polarity versatility on transformer machines.
Moving away from the aggressive dig, titania-based coatings provide a much smoother, quieter arc. These rods are commonly used for general fabrication due to their ease of use and aesthetically pleasing beads.
When toughness and crack prevention are non-negotiable, low-hydrogen coatings reign supreme. These classifications are the backbone of structural steel welding and are heavily referenced within the AWS A5.1 specification for their strict moisture control requirements.
Note: E7018 must be kept dry. Low-hydrogen coatings are extremely moisture sensitive, as absorbed water introduces hydrogen into the weld. Always store these rods in a heated rod oven to meet the recommendations set by Lincoln Electric’s AWS classification guidelines.
Rounding out the chart are the lesser utilized, yet highly specialized coatings:
By memorizing these last digit codes, you are no longer guessing your polarity or penetration. From the digging roots of E6010 to the pristine, crack-resistant passes of E7018, the final digit is your blueprint. For any shop looking to expand their capabilities, be sure your welding facilities accommodate proper storage for these consumables, solidifying both quality and safety for every project ahead.
The digits before the dash tell you strength, position, and coating. Everything after the dash tells you how good that electrode really is. Suffixes are the fine print that separates a general-purpose rod from one built for a coded pressure vessel or a subzero pipeline. Miss them, and you can pass a tensile test yet still fail a hydrogen or impact-toughness requirement. Read them correctly, and you’ll match filler to service conditions every time.
Add -1 and the electrode guarantees better toughness and ductility, verified by Charpy V-notch impact testing at low temperature. On an E7018-1, that impact rating holds down to roughly -40°F (-40°C). Plain E7018 is normally tested at a warmer -20°F. So if you’re welding structural steel that will see winter service or refrigeration duty, the -1 version is often the only compliant choice. It costs a little more, but a cracked weld in cold service costs a lot more. On bridge work, cold-storage racks, and anything headed outdoors, that small price difference is cheap insurance against a costly failure.
These letters track diffusible hydrogen, the invisible culprit behind underbead cracking. The number is the maximum diffusible hydrogen allowed in milliliters per 100 grams of deposited weld metal. H4 means no more than 4 mL, H8 means 8 mL, and H16 means 16 mL. Lower is better. Those figures come from a standardized test method, so the ratings are directly comparable from one brand to the next.
Quick Note: Hydrogen cracking gets worse as steel strength rises, so H4 rods are common on high-strength and thick-section work. As the AWS A5.1 specification shows, the H designator is an optional classification applied only when the manufacturer tests and certifies to it.
The R designator means the electrode meets AWS absorbed-moisture requirements, so its coating resists picking up water from humid air. In plain terms, a properly stored R rod can sit out for about nine hours after you open a sealed package before it needs redrying. That’s a huge practical advantage on a long shift or a humid site, where a non-R low-hydrogen rod can absorb moisture fast and quietly push your hydrogen level back up. Keep it sealed and dry it when the clock runs out, and it holds that rating; leave it in a damp truck bed overnight and you’re re-baking before the next pass.
An M suffix — as in E7018M — means the electrode meets most military requirements. These rods carry greater toughness, tighter moisture limits, and mandatory diffusible-hydrogen limits. You’ll see them specified on defense, shipbuilding, and critical structural work where the extra documentation and consistency are worth the premium. In practice, that means tighter process control at the mill and a paper trail inspectors can follow.
On low-alloy electrodes, the suffix after the dash signals the approximate chemical composition of the deposit rather than a performance feature. Common examples:
These alloyed deposits deliver creep strength, corrosion resistance, and elevated-temperature performance that plain carbon rods can’t match. The Lincoln Electric classification guide maps each suffix to its chemistry, and matching it to the base metal is essential — the wrong alloy suffix is a mismatch you can’t weld your way out of.
Let’s decode a complete code, one piece at a time:
| Part | Meaning |
|---|---|
| E | Arc welding electrode |
| 80 | 80,000 psi minimum tensile strength |
| 1 | Usable in all positions |
| 8 | Iron-powder, low-hydrogen coating; AC or DCEP |
| -B2 | Deposit is roughly 1.25% Cr, 0.5% Mo |
| H4 | Max 4 mL diffusible hydrogen per 100 g |
| R | Moisture-resistant coating |
Read together: an all-position, 80 ksi, low-hydrogen electrode that deposits a chrome-moly weld with very low hydrogen and a moisture-resistant coating — a rod aimed squarely at high-integrity, code-driven work.
Learning to read these suffixes pays off just as much on wires and other processes; the same logic applies to the filler codes covered in our flux-cored welding guide and to the settings you dial in after choosing a rod. For deeper hands-on time with low-hydrogen technique, see our welding practice guide.
After learning how to read stick rod codes, it can be tempting to assume that other filler metals follow an entirely different system. However, the logic carries over to the vast majority of wire-fed processes. The American Welding Society (AWS) still uses strength, position, and usability to classify consumables, but it adapts the format to fit flux-cored, solid MIG, and stainless filler metals. With a little practice, the codes for flux-cored and MIG will be just as easy to decipher as any E6010 or E7018 rod.
Unlike a solid stick electrode, flux-cored wire is hollow and filled with flux. Because of this, AWS classifies these consumables under AWS A5.20, which covers carbon steel flux-cored electrodes. The most common examples are E71T-1 and E71T-11, both of which directly mirror the structure of a stick electrode code.
Breaking down E71T-1 is the easiest way to see the pattern. The “E” stands for electrode, the “7” denotes a minimum tensile strength of 70 ksi, and the “1” means it is approved for all welding positions. The “T” is the key differentiator, as it indicates that the wire is tubular rather than solid. Finally, the trailing “-1” refers to the shielding gas and usability. E71T-1 is a gas-shielded FCAW electrode that requires either CO2 or an Ar/CO2 mix to protect the weld pool.
By contrast, E71T-11 is self-shielded, meaning its flux produces its own shielding gas as it burns. The same first four markers apply, but the “-11” denotes its self-shielding capabilities. This makes it ideal for outdoor work, field repairs, or jobs where hauling a gas cylinder is impractical. For those working off-grid, our guide to gasless MIG welding goes into greater depth on these wires. When setting your machine, be sure to reference polarity for flux core welding, as self-shielded wires often differ from their gas-shielded counterparts.
Quick Note: Not all flux-cored wires share the same polarity. Always check the wire manufacturer’s data sheet before striking an arc, as incorrect polarity is one of the leading causes of porosity and poor penetration.
For Gas Metal Arc Welding (GMAW), also known as MIG, solid filler metals fall under AWS A5.18. These are classified with an “ER” prefix rather than a lone “E”. In ER70S-6, the “ER” signifies an electrode or rod filler metal, the “70” indicates a minimum tensile strength of 70 ksi, the “S” denotes that it is solid, and the “6” reveals its chemical composition and deoxidizer content.
This chemistry is what makes certain wires more forgiving. For example, ER70S-6 contains higher levels of silicon and manganese than ER70S-3, allowing it to weld through light rust, mill scale, or surface contamination with less porosity. These small differences can be crucial when learning how to use a wire welder or troubleshooting good and bad MIG welds. Proper setup, including your contact tip, wire feed speed, and gas coverage, will always matter just as much as the code itself.
When corrosion resistance becomes the priority, stainless filler metals take center stage. These are governed by AWS A5.9 and follow a similar “ER” structure for bare wires used in MIG and TIG. Common designations include ER308L, ER309L, and ER316L.
The three-digit number, such as 308, 309, or 316, corresponds to the stainless alloy family. The suffix is just as telling: the “L” stands for low carbon. Lower carbon content helps prevent carbide precipitation, which can lead to intergranular corrosion in certain service conditions. For instance, ER308L is often used for 304 stainless base metals, ER309L is a popular choice for joining dissimilar steels, and ER316L is favored for applications exposed to chlorides or harsh chemicals.
While these wires are most common in TIG and MIG, their classification still abides by the same principle of encoding strength, form, alloy, and modifiers into one string. As outlined by Lincoln Electric’s AWS classification guide, this consistency allows welders to compare consumables across processes with confidence.
The electrode number meaning does not stop at stick rods. From gas-shielded E71T-1 to self-shielded E71T-11, from forgiving ER70S-6 to corrosion-resistant ER316L, AWS codes are designed to be a universal language. By learning to read each piece of the string, you can select the correct filler metal for any job, cut down on costly rework, and weld with far greater certainty in the shop or in the field.
Every one of these errors shows up in real shops, often on the same afternoon. None are exotic — they’re simple misreads of the code you just learned to decode, and each one has an easy fix.
They look alike, they’re both 1/8-inch, so they must do the same job — right? Wrong. E6013 is a rutile, all-position rod with modest 60 ksi tensile and fuss-free AC/DC behavior. E7018 is a low-hydrogen, 70 ksi electrode that runs smoother, deposits stronger metal, and demands dry storage. Swap one for the other and you change strength, hydrogen exposure, and technique. The price of that mix-up is a bead that either under-matches the base metal or cracks from trapped hydrogen — and no amount of grinding fixes either. Fix: read the strength and coating digits before you grab a rod, and match them to the drawing or job spec, not the bin.
E6010 is designed for DCEP (electrode positive). Put it on AC and the arc stutters, spatters, and may refuse to re-strike. That’s because the coating chemistry doesn’t support alternating current. E6011 uses a slightly different coating that adds arc stabilizers, making AC workable — which is the real reason both rods exist. Fix: check your machine’s polarity output and the electrode’s AC/DC rating before striking an arc; a DCEP-only rod needs DC. If polarity trips you up, our guide to TIG welding polarity explains how electrode-positive and electrode-negative arcs actually behave. It sounds obvious, but polarity mistakes are one of the most common reasons a weld simply won’t run — check your leads before you blame the rod.
E7018’s low-hydrogen coating is hygroscopic — it drinks moisture from the air. Damp rods release hydrogen into the weld, causing porosity and, worse, hydrogen cracking that can appear hours or days later. Fix: keep them in a holding oven around 250–300°F, and treat roughly 4 hours of field exposure as the limit before redrying. This is exactly the shop discipline covered in our guide to planning and setting up a safe shop.
Quick Note: A rod left open overnight isn’t automatically ruined — but it must be redried to the manufacturer’s schedule before it goes into any code weld.
A 1/8-inch rod is a 1/8-inch rod, so any of them will do? No. Diameter controls amperage and deposition, but strength and position decide whether the weld is correct. A vertical-up joint needs an all-position rod; a high-strength base metal needs a matching 70 or 80 ksi electrode. Fix: pick diameter for joint fit and thickness, then confirm the rest of the code:
The “70” in E7018 is minimum tensile strength in ksi — not yield. Yield is usually a good deal lower. Match the base metal to its specified strength requirement, not by assuming the number is yield. This distinction is spelled out in the filler-metal classifications at AWS A5.1/A5.1M. Fix: check the base metal cert and the drawing’s filler call-out, then verify the electrode’s tensile per its AWS classification.
Throwing rods in a damp toolbox or baking them at the wrong temperature ruins them. Overheating a low-hydrogen coating can damage it; under-drying leaves moisture in. Fix: follow the manufacturer’s recommended oven and redry temperatures and holding times, keep sealed containers until use, keep original lot info, and log exposure. Once a rod leaves its sealed container the clock is running, so write the open date on the box and nobody has to guess later. For a broader reference, see Lincoln Electric’s AWS classification guide.
Two E7018 boxes can carry different diffusible-hydrogen designators — H4 versus H8 — and different storage demands. Ignore the H-number and you may miss a low-hydrogen spec even with a “correct” 7018. A general-purpose 7018 and a tightly controlled H4 rod may run the same, but they are not certified for the same jobs under a strict procedure. Fix: match the H-designator to the code requirement, and treat stricter ratings as needing tighter oven discipline.
None of this is glamorous, but it’s exactly the kind of habit that builds real skill through deliberate welding practice. Read the code, respect the storage rules, and match the rod to the job — that’s how you stop turning a two-dollar electrode into an afternoon of grinding.
By now, that code on the rod should read like a sentence, not a serial number. The trick is turning that decoding into a fast decision at the bench. Rather than memorizing a giant table, learn the handful of head-to-head matchups that cover most real-world stick welding, then apply a few field rules that keep your bead sound.
These two are cousins. Both are cellulosic, deep-penetrating rods with a forceful arc that bites through rust, mill scale, and dirty steel. The difference is the current. E6010 runs on DC only, typically electrode positive, and it’s the classic pipe-root rod. E6011 is the AC-friendly version — same aggressive dig, but it runs on AC or DC. If your machine only offers AC, E6011 is your answer. If you have DC and want the crispest control on open roots, E6010 stays the favorite. Expect a light, fast-freezing slag and a whip-and-pause technique.
Beginners face this decision most often. E6013 is a gentle, low-penetration rod that starts easily and lays a smooth, cosmetic bead — perfect for thin sheet, light fabrication, and practice coupons. E7018 is the structural workhorse: a low-hydrogen, iron-powder rod that delivers good toughness and is the go-to for code work and low-temperature service. The catch is that E7018 is far less forgiving of damp storage and dirty plate. For building skills on scrap, reach for E6013; for anything that carries a load or gets inspected, reach for E7018 and store it right.
Quick Note: Low-hydrogen rods like E7018 absorb moisture once the package is open. Keep them in a heated rod oven or a sealed container — moisture is the number one cause of porosity and under-bead cracking.
Both are iron-powder, high-deposition rods, but their position limits split them apart. E7014 handles all positions and is a great choice when you need decent deposition with vertical and overhead capability. E7024 is a flat-and-horizontal-fillet specialist that offers high deposition efficiency — roughly 75% — because its heavy coating lets you drag the rod and lay metal fast. Use E7024 for flat work when you want to move product; switch to E7014 the moment the joint goes vertical or overhead.
The tensile digits should meet or slightly exceed the strength of the steel you’re joining. Mild steel (A36) pairs naturally with 60- and 70-class rods. Higher-strength steels call for 80-class and up, and often a matching alloy suffix. Over-matching sounds safe but can create a hard, crack-prone weld that’s less ductile than the parent metal. When in doubt, follow the welding procedure specification (WPS) — it removes the guesswork. The AWS A5.1/A5.1M specification is the authoritative reference for carbon steel electrode requirements.
For a deep dive on one rod, our guide to 3/16 E7018 amperage, polarity, and technique walks through real settings. And if you’re weighing stick against wire, see how gasless flux-cored welding compares for portability and deposition.
Read left to right: E says electrode, the next two digits give minimum tensile strength in thousands of psi, the third digit tells you usable positions, the fourth digit reveals coating, current, and penetration, and any suffix flags hydrogen level or alloying. That’s the whole manual, printed on every rod.
Reading electrode numbers isn’t trivia — it’s the difference between a weld that holds and one that fails inspection. Start with the base metal, pick the strength class, then narrow by position and current. Practice on scrap until the choice becomes instinct; the more you burn rod, the more the code fades and the weld takes center stage. Grab a handful of E6013 for learning and a sealed can of E7018 for the real work, and you’ll be ready for almost anything the bench throws at you.
A classification like E7018 tells you the consumable type (E = electrode), the minimum tensile strength (70 = 70,000 psi), the usable welding positions (1 = all positions), and the flux coating/current type (8 = low-hydrogen iron powder, AC or DCEP). Optional suffixes add alloy, toughness, and hydrogen information. Together these digits let you match the rod to the base metal and the job.
Both are deep-penetrating cellulosic electrodes with 60 ksi minimum tensile strength and all-position capability. E6010 has a high-cellulose sodium coating and runs on DCEP only, while E6011 uses a high-cellulose potassium coating that also runs on AC. E6011 is often chosen when only an AC machine is available.
H4 means the electrode produces no more than 4 mL of diffusible hydrogen per 100 g of deposited weld metal, so lower numbers indicate better hydrogen control. The R means the coating is moisture resistant and passes AWS absorbed-moisture testing. Low-hydrogen electrodes are important for crack resistance on thick or high-strength steel.
You can, but E7018 is not ideal for very thin sheet because its medium penetration and heavier current can burn through easily. Beginner-friendly E6013 is usually a better match for thin sheet, while E7018 shines on structural and code-quality welds where strength and low hydrogen matter.
Yes. In the core four digits, the third digit indicates welding position: 1 for all positions, 2 for flat and horizontal fillet only, and 4 for flat, horizontal, overhead, and vertical-down. The value 3 is no longer used because those position classifications are obsolete.
The -1 suffix indicates improved toughness and ductility, giving better mechanical performance at low temperatures, roughly down to -40°F for E7018-1. It is chosen for cold-service or critical applications where impact toughness is specified.
The logic is similar but the letters change. Flux-cored electrodes like E71T-1 use E for electrode, 7 for 70 ksi, 1 for position, and T for tubular, with trailing digits describing shielding gas and usability. Solid wires like ER70S-6 use ER for electrode/rod, 70 for strength, and S for solid, with the last digits indicating chemistry.
Using the wrong polarity can cause a rough, unstable arc, excessive spatter, poor penetration, and an unusable bead. For example, E6010 is designed for DCEP only and does not run properly on AC or DCEN. Always check the last digit and the manufacturer’s data to confirm the correct current before welding.