The Complete Guide to TIG Welding Sheet Metal: Settings, Techniques, and Mistakes to Avoid
The job was supposed to take forty-five minutes. Instead, it ate an entire afternoon, plus a burned-up spool…
READ ARTICLE →The stainless handrail job looked simple enough: three lengths of 1-inch 316 tube, a handful of inside corners, and a client who wanted the welds to disappear under a fine satin brush. I’d TIG-welded mild steel all week and my machine was still set up the way I’d left it. I struck the arc, added a touch of filler, and immediately knew something was wrong. The puddle sat lazy and wide instead of biting in. The tungsten tip glowed cherry red, went molten, and dropped a little ball of contamination straight into the weld. By the third pass I was grinding tungsten out of stainless like it was a bad habit.
Nothing about my hand had changed. My amps were close. My gas was argon. The tungsten was the right size. What had changed — what I’d failed to check after swapping machines between shops — was the polarity. The leads were reversed, the torch was on electrode positive, and every ounce of arc heat that should have gone into the stainless was going into my tungsten instead.
If you searched for stainless tig welding polarity, here’s the answer you came for, stated plainly: stainless steel is TIG-welded on DCEN — direct current electrode negative, also called straight polarity. The torch lead goes to the negative terminal, the work clamp goes to the positive terminal, and roughly 70 percent of the arc’s heat lands in the workpiece while about 30 percent stays on the tungsten. That single setting is the reason the arc stays stable, the tungsten keeps its sharp point, and the bead ties into the joint instead of sitting on top of it.
That’s the short version. The useful version — the one that keeps you from repeating my scrap-pile afternoon — covers why DCEN is right, what happens when you run DCEP or AC on stainless by mistake, how to set up the machine and verify the leads, which tungsten and gas and filler go with the setting, how to dial amperage to material thickness, and how to spot polarity problems in a finished bead before the inspector does. We’ll work through all of it.
Polarity is simply the direction of direct current through the welding circuit. A DC welding machine has two terminals, a negative and a positive. Whatever you clamp to the negative terminal becomes the cathode during the arc; whatever is clamped to the positive becomes the anode. Electrons travel from the cathode to the anode through the arc stream, and ions travel the opposite way. Where those charged particles land is where the heat goes — and that is the entire reason polarity matters.
In gas tungsten arc welding, the electrode is non-consumable. The tungsten only has to survive the arc, not melt into it. So the smart engineering choice is to point the majority of the heat away from the electrode and into the joint. That is exactly what DCEN does:
Flip the leads and everything reverses. On DCEP (direct current electrode positive), the tungsten becomes the anode, electrons slam into it, and roughly 70 percent of the arc heat loads onto an electrode that was never designed to absorb it. On AC, the polarity flips 100 or 120 times a second, splitting the heat roughly evenly and giving you half the cleaning action and half the penetration of each DC mode.
Every AC/DC TIG machine gives you three usable choices of welding current. Knowing what each one does makes the right answer for stainless obvious rather than memorized.
| Current type | Electrode polarity | Heat split (work / tungsten) | Oxide cleaning | Penetration | Typical use |
|---|---|---|---|---|---|
| DC straight polarity (DCSP / DCEN / DC−) | Negative | ~70% / 30% | None | Deep, narrow | Stainless, carbon steel, titanium, copper, nickel alloys |
| DC reverse polarity (DCRP / DCEP / DC+) | Positive | ~30% / 70% | Strong | Shallow, wide | Rarely used in GTAW; historically thin sheet, some GMAW |
| AC with high frequency | Alternating | ~50% / 50% | Yes, each half cycle | Moderate | Aluminum, magnesium, AC balance experiments |
Read that heat column twice, because it is the whole story. On DCEN the workpiece is the anode and collects the lion’s share of the energy. On DCEP the tungsten is the anode and collects the lion’s share of the energy. Manufacturers publish these splits — CK Worldwide’s technical guide lists DCSP at 70 percent work / 30 percent electrode, DCRP at 30/70, and AC at 50/50 — and they hold up closely enough in the field that you can feel the difference in one arc start.
Stainless steel is a poor conductor of heat compared with mild steel, and it’s a strong, tough alloy that work-hardens. Both properties push you toward the same polarity choice.
Penetration discipline. Because heat doesn’t travel far through stainless, a shallow arc leaves you chasing fusion. DCEN’s concentrated, deep-penetrating arc drives heat into the root of the joint at moderate amperage, so you can get full fusion without flooding the whole part with heat. On a butt joint in 16-gauge 304, that’s the difference between a bead that has washed into both walls and a bead that’s bridging a cold root.
Tungsten economy. A 1/16-inch 2% lanthanated tungsten rated for roughly 120–150 amps on DCEN can handle only a fraction of that on DCEP before the tip melts. Stainless work is full of long, slow, precise runs — handrails, sanitary fittings, exhaust sections — where you reposition often and don’t want to regrind constantly. DCEN keeps the point sharp and the arc predictable.
No stubborn oxide to fight. Aluminum needs the electrode-positive half of an AC cycle because aluminum oxide melts around 3,700°F while the base metal melts near 1,220°F. Stainless doesn’t present that problem. Its chromium oxide film is thin and melts close to the base metal, so the arc simply melts it away as the puddle forms. You don’t need — and don’t want — to spend half your cycle on cleaning. If you want the background on why aluminum is the exception, our piece on DC welding aluminium and when to use it explains the oxide chemistry in depth.
Stable arc at low amps. Thin stainless is where polarity errors show up fastest. DCEN gives a crisp, repeatable arc that will start and hold down around 20–30 amps on sheet, which is where most stainless fabrication actually lives.
DCEP on a TIG machine is the polarity most likely to destroy an afternoon. The failure sequence is predictable:
In short: reversed polarity on stainless buys you cleaning action you don’t need and costs you the penetration, arc stability, and electrode life you do need.
AC is more forgivable than DCEP but still wrong for stainless. Half of every cycle is electrode positive, so half your heat goes into the tungsten and half of your penetration is missing. The published guidance is blunt about the trade: stainless can be welded on AC, but you’ll need roughly 25 percent more amperage to get the same result as DCEN, and the bead comes out wider and shallower.
There’s also a productivity angle. Stainless pipe and tube work — the stuff that shows up in food plants, breweries, and pharmaceutical runs — is slow, precise, and fusion-critical. Spending half of each cycle on a cleaning action the metal doesn’t require makes every pass take longer for no metallurgical benefit. On thin sheet, AC also produces a softer, mushier puddle that is harder to control during starts, stops, and tie-ins.
The one scenario where AC on stainless gets discussed is heavily scaled, contaminated, or painted material where an operator wants the scrubbing action of the positive half cycle. The better answer is almost always to clean the metal with a stainless wire brush and a solvent wipe before striking an arc, then run DCEN where the process is designed to work.
Polarity isn’t only an electrical abstraction — it has a visible signature. Once you know what a correct DCEN stainless arc looks like, you can diagnose a wrong setting in under five seconds without ever touching a meter.
Stainless doesn’t exist in isolation. Most shops that TIG stainless also touch the other metals on this list, and the polarity rules are closely related.
| Material | TIG polarity | Why |
|---|---|---|
| 304 / 316 stainless steel | DCEN | Chrome oxide needs no cleaning; max penetration, cool tungsten |
| Duplex and 2205 stainless | DCEN | Same as austenitic; heat input control matters more than polarity choice |
| Carbon and low-alloy steel | DCEN | No refractory oxide; deep, narrow fusion |
| Titanium and zirconium | DCEN | Clean, focused heat; strict gas coverage required |
| Copper and brass | DCEN | High conductivity demands concentrated heat input |
| Nickel alloys (Inconel, Monel) | DCEN | Heat-resistant alloys respond poorly to split heat cycles |
| Aluminum | AC (with high frequency) | Al₂O₃ melts at ~3,700°F; needs electrode-positive cleaning |
| Magnesium | AC | Same oxide problem as aluminum |
Print that table and tape it to the machine. Ninety percent of polarity questions in a working shop are answered by the second row from the top.
Knowing the answer is “DCEN” only helps if you can wire the machine to match and then dial in the rest of the setup around it. This section is the practical build-up: leads first, then verification, then amperage, tungsten, gas, filler, and the technique variables that make the polarity pay off.
The physical setup is simple, but it’s where most polarity errors are born — usually because a machine got moved, a torch got swapped, or someone borrowed the TIG rig to run stick electrodes and never switched it back.
On modern inverter TIG machines the polarity is often fixed internally for the TIG process — you select “TIG” and the machine sets electrode negative automatically, and many units won’t let you run TIG on DCEP at all. Older transformer machines and multiprocess units that share stick and TIG outputs are where the risk lives, because there the lead connections are yours to get right.
Before you commit to a joint, verify. Three quick methods, in order of speed:
Polarity sets the character of the arc; amperage sets its size. On DCEN, the standard working rule for stainless is roughly 1 amp per 0.001 inch of material thickness for a butt joint in flat position, then adjust by puddle behavior, position, and joint design.
| Material thickness | Starting DCEN amperage | Typical tungsten | Typical filler | Notes |
|---|---|---|---|---|
| 22 gauge (0.6 mm) | 15–30 A | 1/16 in (1.6 mm), 2% lanthanated | 0.030–1/16 in ER308L | Pulse helps enormously; watch for burn-through |
| 18 gauge (1.2 mm) | 30–55 A | 1/16 in (1.6 mm) | 1/16 in ER308L | Standard sheet-metal range |
| 16 gauge (1.6 mm) | 40–70 A | 1/16 in (1.6 mm) | 1/16 in ER308L | Classic handrail and duct thickness |
| 14 gauge (1.9 mm) | 55–90 A | 1/16 or 3/32 in | 1/16 in ER308L | |
| 1/8 in (3.2 mm) | 80–130 A | 3/32 in (2.4 mm) | 3/32 in ER308L | Sweet spot for most repair work |
| 3/16 in (4.8 mm) | 110–170 A | 3/32 or 1/8 in | 3/32 or 1/8 in ER308L | Multi-pass; clean between passes |
| 1/4 in (6.4 mm) | 150–220 A | 1/8 in (3.2 mm) | 1/8 in ER308L | Consider a bigger cup and higher gas flow |
| 3/8 in (9.5 mm) and up | 200–300 A+ | 3/16 in or twin 1/8 | 3/16 in ER308L | Chill blocks or heat sinking recommended |
Two corrections beginners consistently forget. First, aluminum-style “1 amp per thousandth” thinking runs hot on stainless because stainless doesn’t wick heat away — the puddle stays put and grows. Most welders end up slightly below the rule and let travel speed make up the difference. Second, position changes the number: vertical-up and overhead both want roughly 10–15 percent less current than flat, because the puddle has gravity fighting it.
Foot-pedal control is effectively mandatory for quality stainless work. Polarity gives you the right arc character; the pedal lets you modulate heat within a single joint — backing off for a thin edge or a stop-start, surging for a root pass, easing down into a crater fill. Running a fixed-amperage torch on stainless sheet is a reliable way to blow corners.
Electrode choice interacts with polarity more than most welders realize. On DCEN, the tungsten is the cool side of the arc, so it doesn’t need the extreme heat resistance that a thoriated electrode offers on AC — but it does need a point that survives hundreds of starts.
| Tungsten type (AWS color) | DCEN suitability on stainless | Character |
|---|---|---|
| EWG — 2% lanthanated (blue) | Excellent — best all-round choice | Starts easily, holds a fine point, works on AC and DC, non-radioous handling concerns |
| EWCe — ceriated (gray) | Excellent | Stable low-amp DC arc, holds point well, a favorite for sheet stainless |
| EWT — thoriated (red) | Very good | Traditional workhorse, slightly better current capacity, requires careful grinding and dust control |
| EWLa — 1.5% lanthanated (gold) / Yttriated (orange) | Very good | Fine point retention, good on thin stainless and on AC if the machine does aluminum too |
| EWP — pure (green) | Poor on DC | Designed for AC on aluminum; forms a ball on DC, gives an unstable, wandering arc |
| EZ — zirconiated (brown) | Poor on DC | Also an AC-oriented electrode |
Preparation matters as much as type. Grind tungsten longitudinally — the grind lines must run end to end, parallel to the length of the electrode — on a dedicated diamond wheel. Radial grinding (around the circumference) creates a circular micro-topography that makes the arc wander and wander. The included point angle should be about 30 degrees for most stainless work; a slightly blunter 45–60 degree tip survives long arcs on thicker material better, while a needle-sharp point is best for low-amp sheet work.
Expose the tungsten about 1/4 to 3/8 inch beyond the cup for general work — longer stick-out widens the gas envelope and reduces coverage. If you contaminate the tip, break off the contaminated section or regrind; never just strike an arc and hope the contamination burns off. On stainless, “hoping” deposits tungsten in a weld that will later fail a dye-penetrant exam.
Polarity doesn’t change your gas rules, but the two decisions have to agree. Argon is the baseline for all GTAW of stainless, and the variations are about heat input and travel speed rather than polarity.
Backing gas matters too. On the root side of a stainless weld — pipe, tube, or any joint where the back surface will see service — pure argon purging prevents “sugaring,” the heavy oxide scale that forms when hot stainless meets oxygen. Sugared roots are not cosmetic problems; they destroy corrosion resistance and are rejected in sanitary and process work every time.
Filler doesn’t have a polarity, but it has a chemistry that responds to heat input — and DCEN’s controlled, focused heat is what makes the standard recommendations work.
Match filler diameter to thickness: 1/16 inch for sheet up to about 3/16 inch, 3/32 for 1/8–3/16, 1/8 for 3/16–1/4, and larger for heavier sections. Clean filler with solvent if it’s been handled; fingerprints contain chlorides and oils that leave residues unacceptable in sanitary work.
With the polarity right and the machine dialed, the remaining variables determine whether the weld looks like a professional stainless weld or a repair. These five are the levers:
Everything in this section builds on one fixed decision — electrode negative — and then scales heat, shielding, and technique around it. Get the polarity wrong and no amount of technique saves the weld. Get it right and the process behaves exactly the way the textbooks, the machine charts, and the weld procedures say it should.
Correct polarity is necessary but not sufficient. The most common failures in stainless TIG work come from treating the polarity as “set and forget” while the surrounding habits push the weld back toward the defects that wrong polarity creates. This section covers what actually goes wrong on the bench, how to read the symptoms in a finished bead, and how stainless polarity compares with the other processes you probably also run in the shop.
Welders who cut their teeth on aluminum get used to a machine stuck in AC and never switch it back. On stainless, AC produces a soft, hissy arc, a wide shallow bead, visible tungsten wear, and a nagging feeling that something is “off.” Check the mode switch before you ever blame your technique.
Stick welding on DCEP is normal — E6010 and E6011 need electrode positive — but a TIG torch clamped to the same positive post melts the tungsten in seconds. If your machine runs both processes through the same cables, make a habit of reconnecting and testing every time you switch. This mirrors the logic of DC welding at large, which is why the polarity guide for flux-core welding spends so much time on exactly this kind of lead discipline — you can read the full DCEN-vs-DCEP breakdown in our flux-core polarity guide.
Green pure tungsten is an AC electrode; on DC it balls up and wanders. Reaching for “whatever tungsten was in the drawer” is how DCEN stainless sessions turn into grinding sessions. Keep at least a handful of 2% lanthanated or ceriated sticks in the TIG cart.
When a stainless bead sits wide and cold, the instinct is to add amps. On reversed polarity, adding amps only roasts the tungsten faster. Diagnose polarity first, then amperage. The note callout earlier about the three-second tungsten test exists precisely because of this mistake.
A poor workpiece connection raises resistance in a circuit that is already voltage-sensitive at low amp settings. With DCEN, the workpiece is the positive side of the arc; a bad ground connection heats up, drops voltage, and can make the arc behave erratically in ways that get blamed on polarity.
Hot stainless discolors when it meets oxygen during cooling. If you kill the gas at the same instant you lift the torch, the trailing edge of the bead grays out even on perfect DCEN. Give the gas a few seconds to cover the cooling zone.
Stainless holds heat roughly three times less effectively than carbon steel spreads it away. Running mild-steel habits — high amps, slow travel, long root baths — on stainless produces warp, sag, and sugar before the pass is half over, regardless of correct polarity.
A finished bead is a diagnostic readout. Here’s how to decode the common signs.
| Symptom in the weld | Most likely cause | Fix |
|---|---|---|
| Wide, flat bead with a gray, crusty surface | AC mode left on, or DCEP partially active | Switch to DC, verify torch is negative |
| Tungsten balls up or slumps in seconds | DCEP current flow, wrong tungsten type, or excessive amperage | Verify leads; use 2% lanthanated/ceriated; lower amps |
| Sharp, narrow, but bluish-purple bead | Correct DCEN but too hot or too slow | Lower amps or increase travel speed |
| Grays under the bead face (“sugar” appearance) | Lost argon coverage — wrong nozzle, gas too low, too much torch angle, or no post-flow | Raise flow, shorten stick-out, reduce angle, add post-flow |
| Tungsten flakes visible in the weld | Contaminated electrode dropped into puddle | Regrind tungsten, adjust polarity/gas before restarting |
| Crater depression or crater crack at the stop | Fast arc-out without current taper | Fill crater; use torch pedal taper or timer-based down-slope |
| Lack of fusion at the root of a fillet | Too little heat on a cold joint, often compounded by wide arc | Tighten arc length, raise amps on DCEN, direct heat at the root |
| Distortion or warping of the sheet | Too much heat input overall | Lower amps, use pulse, tack and stagger, use chill backup |
Wrong polarity isn’t just an aesthetic problem on stainless — it’s a metallurgical one. Austenitic stainless becomes “sensitized” when it spends time in roughly the 800–1,600°F band. Chromium combines with carbon at grain boundaries to form chromium carbide, leaving the surrounding metal depleted of chromium — and chromium depletion is where corrosion resistance goes to die. In service this shows up as intergranular corrosion, weld decay, or cracking in chloride service.
Running DCEP or AC on stainless forces you to either overheat the part or leave a cold, unfused root. Both outcomes push the weld toward sensitization territory or toward a weak structural joint. DCEN’s efficient heat transfer lets you deposit the required heat in a narrow window, minimizing the time the metal spends in the dangerous temperature band. That’s one more reason code work on stainless — pipelines, sanitary tube, pressure vessels — states polarity in the qualified procedure: a wrong setting on the machine can quietly change the metallurgy of the joint nobody will inspect until it fails.
Because stainless traps heat, thin sections warp and distort long before they reach the temperatures that harm chemistry. Options in order of preference:
One of the fastest ways to internalize the TIG answer is to compare it with the polarity rules for the processes around it, because they are deliberately different.
| Process | Stainless wiring | Why it differs from TIG |
|---|---|---|
| GTAW (TIG), stainless | DCEN (electrode negative) | Non-consumable tungsten stays cool; heat goes to the joint |
| GMAW (MIG), stainless | DCEP (electrode positive) — always | Consumable wire needs ~70% of the heat at the electrode tip to melt and deposit quickly; wire manufacturers require DCEP |
| SMAW (stick), stainless electrodes | DCEP recommended for most austenitic electrodes (E308-16, E316-16) | Flux and coating chemistry; DCEP gives the right melt-off and penetration for covered electrodes |
| FCAW (flux-core), stainless | DCEP is standard | Gas-shielded flux-core wires are designed for electrode positive |
| TIG, aluminum | AC | Refractory oxide needs electrode-positive cleaning |
Notice the pattern: the same material reverses its polarity rule depending on whether the electrode is consumed or not. Stainless TIG is DCEN, stainless MIG is DCEP, and stainless stick is DCEP. The reason is the heat balance — which side of the arc needs the energy. The more conventional surface, the more aggressive the polarity. This is exactly why you can’t copy a friend’s MIG habit onto a TIG torch and survive the first minute, and why the flux-core vs. MIG “is it wired the same” question keeps coming back to the same leads.
If your machine has pulse, add it to the stainless toolkit. Pulse does not change polarity — it holds DCEN throughout — but it changes the duty cycle of the heat.
On sheet stainless, the biggest practical benefit is that you can run a hotter peak for good fusion while the background period limits total heat input, which translates directly into less warp and discoloration. Pipe welders use pulse to hold a tight root without sugar while keeping the back bead consistent. The settings are machine-specific, but the principle — DCEN, then modulate current within the arc — is the modern stainless recipe.
Polarity on paper is one answer; polarity under real conditions is the whole process. This final section ties the DCEN decision to the work that actually pays for it — the applications, the code requirements, the safety considerations, and the questions every welder asks when they’re two hours in and the bottom line hasn’t moved.
Once polarity stops being a question mark, the same DCEN setup carries across a surprisingly wide range of stainless applications, because the underlying constraint is always the same: controlled heat input into a metal that doesn’t let go of it.
In each case the discipline is identical: verify electrode negative, set amperage to thickness, argon to the joint, tungsten prepared, filler matched — and the welds come out predictable enough that inspectors sign them on the first pass.
If stainless work in your shop is inspected or certified, polarity stops being a preference. It becomes an audited parameter. The standards are worth knowing by name:
Practically, this means two things. First, your welder qualification card lists current type (GTAW) and polarity (electrode negative for steel/stainless) — that’s the “process, polarity” line that never changes on the exam coupon. Second, if someone rewires your machine to the wrong polarity, you’re not just making a bad weld — you’ve removed the joint from the qualified process. Time in front of an inspector is a good reason to do the 30-second polarity check from Part 2 every single job.
DCEN keeps your tungsten alive and your beads square, but it does nothing about the fume. Stainless TIG produces less visible fume than MIG or stick, which makes it sneakier — small doses of serious metals, delivered quietly.
Chromium and nickel. Stainless contains chromium (12% and up) and often nickel. During welding, chromium is converted to hexavalent chromium, Cr(VI) — a known carcinogen that can damage the eyes, skin, nose, throat, and lungs. OSHA’s Permissible Exposure Limit for Cr(VI) is 5 micrograms per cubic meter as an 8-hour time-weighted average, and the agency has a dedicated standard (29 CFR 1910.1026) with monitoring, training, and engineering-control obligations before respiratory protection becomes a substitute. NIOSH singles out chromium and nickel exposure as the driver of the elevated lung-cancer risk reported in studies of welders — a body of evidence behind its recommendation that exposure to all welding emissions be reduced to the lowest feasible level.
Ultraviolet radiation. GTAW — and TIG in particular — produces UV intensities far higher than stick welding, potentially multiples greater, which is why full coverage of skin and a proper lens are non-negotiable. The eye protection question is important enough that it has its own dedicated treatment — our guide on protective eyewear for welding covers lens shades and the physics of arc flash in detail.
Practical controls:
Across shops, the people who make stainless TIG look effortless share a few habits. None of them are secrets; all of them are consistent.
One more bench observation worth keeping: beginners who blame “the machine” for stainless problems are nearly always about to discover reversed leads. The machine is usually fine. The leads are not.
DC — direct current electrode negative. Stainless doesn’t need the oxide-cleaning benefit of AC, and AC’s half-and-half heat split wastes energy and wears the tungsten on a metal that thrives on focused heat.
Select the TIG mode on the machine (most inverters do this internally) and, where leads are user-connected, move the torch to the negative post and the work clamp to the positive post. Verify with a scrap-start test before committing to the job.
You can strike an arc, but the tungsten will melt within seconds — DCEP delivers roughly 70% of the arc heat to the electrode. It is not a production option; it’s the quickest way to a contaminated weld.
Not the machine, but it degrades the weld: shallow fusion, tungsten contamination, heavy discoloration, and possible sensitization of thin austenitic sections if heat input runs away. Fix the mode before welding any real joint.
DCEN is standard for all austenitic stainless pipe including 316/316L. Root runs want argon backing gas; filler is ER316L; amperage follows the wall thickness and joint design per your WPS.
No. Pulse alternates the current level between peak and background while staying pure DCEN. The polarity rule never changes on stainless; pulse only modulates heat.
The pure tungsten forms a ball and the arc wanders. Grey-yellow lanthanated or ceriated (or thoriated, handled carefully) electrodes carry DCEN stainless work with a stable, tapered point.
Yes — use ER309L filler, keep DCEN exactly as you would for stainless, and control dilution so the weld metal lands in the austenitic band where 309 is designed to run.
Heat and oxygen. Correct this by checking polarity (must be DCEN), confirming argon coverage and post-flow, reducing amps, and increasing travel speed so the bead exits the hot zone quickly.
Because stainless MIG runs DCEP and TIG runs DCEN. The same work clamp polarity doesn’t transfer between processes; the electrode is consumed and needs its heat in one case, and is not consumed and must stay cool in the other.
The whole discipline of stainless TIG welding can be compressed to one sentence: put the heat where the metal is, not where the tungsten is, and let everything else follow. DCEN is the electrical expression of that idea — connected negative, concentrating ~70% of arc energy into the joint, keeping the tungsten point sharp and the process stable. Wrong polarity on stainless shows up in seconds (a molten tungsten tip) and in inspection reports months later (reject-level fusion and integrity issues). Right polarity is invisible: the puddle flows, the bead is silver, the tungsten survives the day, and the parts pass.
Set the machine to DC electrode negative. Grind a proper point on a 2% lanthanated or ceriated electrode. Match amps to thickness, argon to the joint, filler to the alloy, and your hand to the puddle. That is not a recipe — it’s a routine, and it’s the routine that makes the search that led you here feel like it was worth it.
If you’d rather hand your stainless work to the same instinct that governs the rest of your TIG life, keep the short rule somewhere visible: DC. Negative. Every time.