Stick Electrode Numbers Explained: How to Read Every AWS Electrode Code

By sohagarbin October 14, 2026 35 min read

Table of Contents

Why Stick Electrode Numbers Matter More Than You Think

You’re standing in front of a wall of welding rods, and every label reads like a secret code: E6010, E6011, E7018, E7024. The rods look nearly identical — same chalky coating, same stubby length — yet the counter guy asks which one you need, and you just nod like you know. Then you walk out with the wrong rod, or you stand there guessing while the line builds behind you.

That wall of rods feels intimidating because the differences hide inside the coating and the chemistry, not the appearance. A fast-freeze E6010 that gouges through dirty, rusty steel looks exactly like a low-hydrogen E7018 that lays down smooth, strong beads on clean plate. Grab the wrong one and you’ll fight the arc all afternoon — or worse, put a weld on a critical part that an inspector will reject.

Here’s the thing: those numbers aren’t decoration. In Shielded Metal Arc Welding (SMAW) — what everyone calls “stick” — the electrode does two jobs at once. It melts to become the filler metal that fills your joint, and the flux coating burns to create its own shielding gas and slag. That self-shielding trick is why stick welding works in wind and rain, and it’s the big difference from MIG and flux-cored processes that rely on gas or a flux core in the wire itself. If you’ve read our guide to gasless MIG welding, you already know how much shielding matters — stick just builds it into the rod.

Because the electrode is doing so much, the printed code carries a lot of information. That code follows the American Welding Society (AWS) classification system — the universal language shared by every manufacturer, distributor and inspector. For carbon steel covered electrodes, the rulebook is the specification AWS A5.1/A5.1M, and each new edition keeps the naming consistent so a rod bought in Ohio behaves the same as one bought in Osaka. You can browse the standard yourself through the AWS A5.1/A5.1M 2025 preview.

Manufacturers like Lincoln Electric and Hobart Brothers publish free classification charts built directly on the AWS system, so the code you learn here matches the charts on their websites and the labels on their boxes. The American Welding Society maintains the standards behind all of it.

A quick definition helps set the stage. AWS A3.0 defines an electrode as a component of the welding circuit through which current is conducted and that terminates at the arc, molten conductive slag, or base metal. In plain words, the rod is both the wire and the torch tip — everything happens at that one consumable stick.

Quick Note: The full code is printed on every single electrode and on the packaging. That means you can verify what you’re about to strike at the point of use, not just at the supply house.

The letter at the front ties it all together. The prefix “E” simply stands for “electrode for arc welding.” Every stick rod you pick up starts that way. What follows is where the real decoding begins.

What This Guide Will Teach You

By the end of this article, those mysterious digits will read like a sentence. We’ll break down what each number means — tensile strength, welding position, coating type and usable current — then show you how the code connects to polarity and machine settings. You’ll learn how suffixes like H4R and -1 change the story, and you’ll decode every common carbon steel rod from E6010 to E7028. We’ll even cover the picky stuff, like why a 3/16 E7018 needs its own amperage window.

We’ll also cover the mistakes that cost real money: grabbing an all-position rod for a flat weld that a fast-fill rod would finish cheaper, or running an E7018 on the wrong current and watching the arc stub out. When it’s matched correctly, a rod practically runs itself. See our welding practice guide for building that instinct.

One more promise: no more nodding along at the counter. By the end, you’ll be able to read any carbon steel stick electrode code on sight — and know exactly which rod your job needs.

Anatomy of a Stick Electrode Code: E + Digits Decoded

Before we get into the individual numbers, it helps to see the whole label as one template. Once you know where each piece of information lives, any electrode code becomes readable at a glance — whether it’s the classic E7018 or the beefier E10018. The rules come straight from AWS A5.1/A5.1M, the master specification for carbon steel stick electrodes.

The Master Template

An American-style SMAW electrode code looks like this:

E  70  1  8

Each block answers a different question. Here’s how the pieces line up:

Part Meaning Example (E7018)
E Electrode E = stick electrode
First two (or three) digits Minimum tensile strength in ksi (1,000 psi) 70 = 70,000 psi
Next-to-last digit Welding position 1 = all-position
Last digit(s) Coating type and current/polarity 8 = low-hydrogen iron powder, AC or DCEP

Read left to right, the code is really a sentence: “This is an electrode, with this minimum strength, usable in these positions, with this coating and current.”

Why Some Codes Have Four Digits and Others Have Five

This is where beginners get tripped up. The position and coating digits always sit at the end — so when the tensile strength climbs into three digits, the whole code stretches to five characters. That’s the elegant part of the system: the position and current information never moves, no matter how strong the electrode gets, so you can always read it from the right.

  • Four-digit codes (E6010, E7018): first two digits = tensile strength in ksi. That gives us 60 or 70.
  • Five-digit codes (E10018, E11018): first three digits = tensile strength. Now we’re at 100 or 110 ksi.

Lincoln Electric’s own classification charts make this easy to spot: E6010 carries 60,000 psi minimum tensile, while E10018 jumps to 100,000 psi. The Hobart Brothers AWS classification poster breaks down every variant the same way.

Quick Note: Count from the right, not the left. The position digit is always the second-to-last character and the coating/current digit is always last. That single habit stops most misreading.

Optional Suffixes: The Extra Bits After the Core Code

You’ll sometimes see letters or numbers tacked onto the end — -1, H4, R, or M. These are optional designators covering things like hydrogen limits, moisture resistance, or impact toughness. They don’t change the core four-or-five digit meaning, and we’ll decode each one in a later section. The best-known example is H4, which caps diffusible hydrogen at just 4 mL per 100 g of deposited weld metal — a number that matters on high-strength or thick-section work.

Worked Example: E7018, Piece by Piece

Let’s run the whole template on one of the most popular rods in the shop:

  1. E = electrode (stick welding consumable).
  2. 70 = minimum tensile strength of 70,000 psi.
  3. 1 = all-position welding capability.
  4. 8 = low-hydrogen, iron-powder coating run on AC or DCEP (electrode positive).

That last digit is doing a lot of quiet work — it tells you the flux chemistry and the current type at once. If you’re still building your feel for polarity and how electrode-positive vs. electrode-negative behaves, our guide to TIG welding polarity: DCEN, DCEP, and AC explained covers the underlying current logic, and the 3/16 E7018 amperage, settings and technique breakdown shows it applied to a real job.

Short Note: For thickness limits and acceptable current ranges on any classified electrode, always cross-check the manufacturer’s data sheet against the AWS specification — the code tells you the category, the sheet tells you the operating window.

With the template locked in, the four building blocks — tensile, position, coating, and current — are ready to be unpacked one at a time. Each one changes what the rod can do and where it belongs, and together they explain why two electrodes with similar strength can behave nothing alike on the bench. And if your goal is cleaner, more consistent beads with whatever rod you pick, the fundamentals in Welding Practice: The Complete Guide to Building Real Welding Skills are worth reading next.

The First Digits: Tensile Strength (And Why 60 vs 70 vs 100 Matters)

Those two digits right after the E are the ones welders argue about most — and the ones most often misread. In E6010, E7018, or E11018, the “60,” “70,” and “110” don’t describe the rod’s coating or its size. They tell you how strong the metal that rod deposits will be once it cools.

Here’s the precise definition: the digits represent the minimum tensile strength of the deposited weld metal, measured in thousands of pounds per square inch (ksi). An E6010 rod lays down weld metal that tests at no less than 60,000 psi. An E7018 delivers at least 70,000 psi. Five-digit codes like E10018 simply push the number to three digits — 100,000 psi tensile strength. That’s the whole code, stripped to its bones, and you can confirm the convention on Lincoln Electric’s AWS classification guide.

Quick Note: The number describes the strength of the weld metal the electrode deposits — not the strength of the steel you’re joining. Confusing the two is the single most common mistake beginners make when reading electrode labels.

Ksi to MPa: A Quick Conversion Table

Most of the world works in megapascals (MPa), while North American codes still use ksi. Here’s how the common families line up. The same pairing appears on the Hobart Brothers AWS classification poster.

Electrode family Tensile (ksi) Tensile (MPa)
E60xx 60 420
E70xx 70 480
E80xx 80 550
E90xx 90 620
E100xx 100 690
E110xx 110 760
E120xx 120 830

Matching the Electrode Family to the Base Metal

How do you pick a family? Start with the base metal. Mild and low-carbon steels — A36, AISI 1018, common structural plate — are comfortably served by E60 and E70 electrodes. Higher-strength steels such as A572 Grade 50, weathering steels, and quenched-and-tempered grades usually call for E80 through E120. Per AWS, matching the electrode to the base metal grade is part of a qualified welding procedure, which is why the family is rarely a free choice on a real job. When the base metal grade is unknown, E70 is the pragmatic default for mild steel — strong enough for most structural work, forgiving enough to run on simple machines. Your welding practice on scrap is a fine place to experiment with different families, but production work follows the print.

It’s Not Just Tensile: Yield and Elongation Matter Too

A tensile number alone never tells the full story. Under AWS A5.1, each classification pairs its tensile requirement with a minimum yield strength and a minimum elongation, so the weld can stretch without snapping. E70xx electrodes require a minimum yield of 58 ksi (400 MPa). E60xx generally sits at 50 ksi (340 MPa), except E6012 and E6013, which each require 55 ksi (380 MPa). Put it together and E7018 must hit 70 ksi (480 MPa) tensile, 58 ksi (400 MPa) yield, and 22% minimum elongation. That trio — not one number — is what a procedure actually tests against.

Why “More Is Better” Is a Trap

New welders often assume the strongest rod wins. It doesn’t. Overmatching a soft base metal with an E110 electrode can drive cracking, especially when the harder weld metal restrains a ductile parent. Undermatching has its own risk: a weld weaker than its parent can quietly become the failure point when the joint is loaded. Higher-strength electrodes also tend to demand more preheat, tighter heat input, and better hydrogen control, all of which multiply the ways a job can go wrong. If you’re working with hardened or unfamiliar steel, it’s worth reviewing what works and what doesn’t when welding hardened steel before committing to a rod.

On engineered work, none of this is guesswork. A Welding Procedure Specification (WPS) names the electrode class, and the welder simply follows it. When you’re the one writing or questioning that spec, you’ll want the current and polarity details sorted too — the same discipline that keeps 3/16 E7018 settings repeatable run after run. Strength is the first decision; the rest of the code refines it.

The Position Digit: All-Position vs Flat-and-Horizontal

Here’s the number most welders ignore until a rod fails the moment they tilt the stinger upward. The position digit sits in the next-to-last slot of the code. In E6010, that lonely “1” tells you more about where you can weld than any other digit. Get it wrong and you’ll fight gravity all day.

Position is exactly what it sounds like. It’s the orientation of the joint in space relative to your body and the pull of gravity. The four fundamental positions are flat, horizontal, vertical, and overhead. Flat is the easy one — you lay the rod down and the molten puddle sits where you put it. Overhead is the nightmare: you’re welding upward against gravity while molten metal tries to drip straight down your sleeve.

That’s the whole reason the position digit exists. Molten weld metal wants to sag or fall in vertical and overhead work, so the electrode’s coating has to freeze the puddle fast enough to beat gravity. A rod that flows beautifully flat can turn into a dripping, sagging mess overhead. The coating chemistry — not the core wire — usually decides this. Fast-freeze coatings like those on cellulosic E6010/E6011 rods stiffen the slag quickly, which is why they handle vertical and overhead so well. Rutile and iron-powder coatings flow more fluidly and freeze slower, so they’re happiest flat.

What Each Position Digit Tells You

  • 1 = All position. Usable flat, horizontal, vertical, and overhead. The classic example is E6013, a gentle rutile rod that’s a favorite for general repair and thin sheet work.
  • 2 = Flat and horizontal fillets only. These rods deposit fast but don’t have the freeze speed for vertical or overhead joints.
  • 4 = Flat, horizontal, vertical-down, and overhead. This is a special case worth remembering. According to Lincoln Electric’s AWS classification guide, the digit “4” can indicate flat, horizontal, vertical-down, and overhead capability — unusual for an iron-powder rod.

In other words, digits 1 and 2 cover the vast majority of rods you’ll grab off the shelf, while 4 is the oddball you’ll encounter on a few specialty electrodes.

The Trade-Off: Speed vs. Flexibility

Flat-and-horizontal-only rods aren’t inferior — they’re specialists. E7024 is the poster child. Its heavy iron-powder coating floods the joint with extra metal, delivering very high deposition rates. In a shop where you’re running long flat fillets on a bench, that speed pays the bills. On the other hand, grab that same rod for an overhead T-joint and you’ll rain molten metal.

If high-deposition automation is your world, the same principle scales up in robotic submerged arc welding, where flat positioning is controlled by the machine rather than the rod’s coating.

Quick Note: The 2025 AWS A5.1 update added Grade 3 radiographic acceptance for E7024 and E7024-1, raising the quality bar for these high-deposition flat-position rods.

How Operators Adapt Across Positions

Even an all-position rod needs technique. Welders adjust three things to keep the puddle under control:

  1. Travel angle and speed — tilting the rod and moving faster helps the puddle freeze before it sags.
  2. Arc length — a tighter arc concentrates heat and gives the molten metal less room to wander.
  3. Amperage — running toward the lower end of the range reduces the puddle size, which matters most overhead and on thin material.

These same muscle-memory habits carry into other processes too. If you’re building bench skills, our guide to welding practice walks through drills that sharpen position control, and understanding TIG welding polarity helps you see how heat direction changes puddle behavior across every process.

Bottom line: read the position digit before you strike an arc. Digit 1 keeps you flexible anywhere on the job site; digit 2 buys you speed on the bench; and the rare digit 4 splits the difference. Match the digit to the joint in front of you, and gravity stops being your enemy.

The Coating and Current Digit: The Most Important Number

If the first three digits tell you how strong and where you can weld, the last digit tells you how the rod welds—and that’s the number that changes everything at the arc. This digit encodes the flux coating chemistry, which in turn dictates the welding current and polarity the electrode accepts. Get it wrong and you’ll fight spatter, porosity, or an arc that simply won’t strike. Read it correctly and a stubborn rod suddenly behaves.

The Complete Coating and Current Chart

Here’s the master reference, straight from Lincoln Electric’s AWS classification guide:

Digit Coating Type Current & Polarity
0 High cellulose sodium DC+ only
1 High cellulose potassium AC, DC+, DC–
2 High titania sodium AC, DC–
3 High titania potassium AC, DC+
4 Iron powder titania AC, DC+, DC–
5 Low hydrogen sodium DC+ only
6 Low hydrogen potassium AC, DC+
7 Iron oxide / iron powder AC, DC+/DC–
8 Low hydrogen iron powder AC, DC+
9 Iron oxide / rutile / potassium AC, DCEP, DCEN

Notice how the polarity rules follow the chemistry. Numbers 0 and 5 run on DC+ only, while 6 and 8 are the low-hydrogen options that tolerate AC as well as DCEP. That single detail decides which machine you can run a rod on. If you’re still fuzzy on how electrode-positive and electrode-negative affect the arc, our polarity guide breaks down DCEN, DCEP, and AC from the ground up.

The Three Coating Families That Matter

Cellulosic (0 and 1): These rods burn a tough cellulose skin that produces a forceful, gas-shielded, deeply penetrating arc. The classic E6010 is DC-only and remains the most penetrating common rod—ideal for pipe root passes and dirty, rusty, or painted metal where you need to punch through contamination. Cellulosic rods also tolerate windy outdoor conditions better than most.

Rutile and titania (2, 3, 4, 9): These coatings are the friendly ones. They strike easily, run smooth, produce low spatter, and leave a clean bead, which is why E6013 is such a popular beginner electrode. The trade-off is shallower penetration, so they are best for sheet metal, general fabrication, and cosmetic beads rather than deep structural work.

Low hydrogen (5, 6, 8): These are the quality rods. They are designed to minimize hydrogen in the weld, which prevents underbead cracking in high-strength steel and thick sections. E7018, the low-hydrogen all-position workhorse, belongs here, and its smooth, quiet arc and higher deposition rate make it the default for structural and code work.

Why Low Hydrogen Deserves Special Respect

The “H” in a suffix like H4R is your clue that moisture control matters. Low-hydrogen electrodes absorb moisture from the air once exposed, and a damp rod deposits hydrogen straight into the weld—the exact thing the coating exists to prevent. That’s why E7018 must be stored in a heated rod oven after opening and used dry. A rod left out overnight is already compromised. For critical welds, follow manufacturer baking schedules rather than guessing, since re-drying temperatures and times vary by electrode type.

Quick Note: If a low-hydrogen rod hisses, sputters, or throws porosity like a fountain, stop and check the moisture, not your technique. A wet E7018 will ruin an otherwise perfect weld.

Note: On high-strength or thick steel, always confirm your polarity match before the first arc—running a DC+ only rod like E7018 on AC works, but running E6010 on AC simply won’t. Double-checking against the chart above takes five seconds and saves a rework. New welders building arc control on these variable rods should pair rod choice with deliberate structured practice so consistency becomes muscle memory.

The last digit, in short, is the personality of the rod: its temper, its appetite for current, and its tolerance for real-world mess. It decides whether you grab a DC machine or an AC one, whether the rod runs smooth or fights you, and whether your weld passes inspection or fails it. Understand it and half your electrode decisions make themselves.

Optional Suffixes: H4R, H8, -1 and What They Add

You’ve decoded the core digits. Now the tail end of a label like E7018-1 H4R throws a curveball. These add-ons aren’t random — they’re promises about diffusible hydrogen and toughness that can decide whether a weld holds in a Minnesota winter or cracks in a critical bridge repair. Most welders never read them. Let’s change that.

The “H” Number: Hydrogen in Plain Numbers

The H designator tells you the maximum diffusible hydrogen the electrode is guaranteed to leave in the weld, measured in millilitres per 100 g of deposited weld metal. The lower the number, the cleaner the weld chemistry.

  • H4 — less than 4 mL/100 g
  • H8 — less than 8 mL/100 g
  • H16 — less than 16 mL/100 g

Hydrogen is the quiet enemy of high-strength and thick-section welds. Trapped hydrogen migrates to the heat-affected zone and can trigger hydrogen-assisted cracking hours or even days after you cool down. A typical E7018-H8 holds a max of 8 mL/100 g, while premium low-hydrogen rods push 3–7 mL/100 g. That difference matters enormously on restraint-heavy joints. Hydrogen atoms are tiny and highly mobile, so they can travel through the metal lattice over time and concentrate wherever stress builds up.

Quick Note: Lower hydrogen = tighter storage discipline. An H4 rod left in a damp rod oven or exposed on a damp bench won’t stay H4 for long. The rating assumes proper handling.

The “R” Suffix: Moisture Resistance That Survives the Field

The R (as in E7018 H4R) means the electrode passed an absorbed-moisture resistance test. In real terms, the coating resists soaking up humidity during exposure — critical when your “rod oven” is a truck bed on a rainy jobsite. The test exposes the electrode to controlled humidity, then checks whether absorbed moisture stays low enough to preserve its hydrogen classification. An H4R rod can sit out briefly and still meet its hydrogen spec, whereas a non-R rod might not. For field work far from power and ovens, that resilience is worth the premium.

The Hobart Brothers electrode classification guide lays out how these optional designators stack on top of the base class, and the AWS A5.1 specification defines the exact supplemental requirements, including improved toughness, ductility, and lower moisture content.

The “-1” Suffix: Improved Impact Toughness

The trailing -1 signals enhanced Charpy V-notch toughness. Here’s the cold-weather payoff:

Electrode Impact Requirement
Standard E7018 20 ft-lb at -20°F (-29°C)
E7018-1 / E7016-1 20 ft-lb at -50°F (-46°C)

That extra 30°F of margin is the difference between a weld that shrugs off a hard freeze and one that shatters under load. If your structure lives in a cold climate — think pipelines, arctic modules, or winter-exposed structural steel — the -1 designation isn’t optional polish; it’s insurance. Specifiers often call out E7018-1 explicitly for low-temperature service because that extra notch toughness is verifiable on a mill certificate. It also pairs naturally with careful joint prep, a topic we cover in our guide to fixing overlap welding defects where toughness and fusion both matter.

Why These Suffixes Aren’t Always Printed

Optional designators are just that — optional. Many manufacturers meet H4 or the -1 toughness silently without stamping it on the rod. Some producers certify the higher grade only on request, so two boxes that look identical can hide very different performance. The only reliable answer lives in the data sheet or certificate of conformance. If you’re welding to a code or a critical spec, never assume. Pull the paperwork.

Note: Low-hydrogen performance is a chain, not a badge. Buy the H4R rod, then store it in a holding oven and use it within the manufacturer’s exposure limits — or you’ve paid for a spec you don’t actually deliver. Good storage habits belong in any well-planned shop, and our welding facilities setup guide covers the equipment side. Strong fundamentals also make these finer distinctions easier to feel at the arc — see our complete welding practice guide for building that skill.

Next, we’ll put every piece together and decode the rods you’ll actually reach for.

Decoding the Common Rods: E6010, E6011, E6012, E6013, E7014, E7016, E7018, E7024 & E7028

Stand in the rod aisle and nine codes do most of the work: E6010, E6011, E6012, E6013, E7014, E7016, E7018, E7024 and E7028. Each digit package follows the AWS classification scheme — read them and choosing a rod becomes a quick decision, not a guess.

Cellulosic Diggers: E6010 and E6011

E6010 (60,000 psi, 1 = all-position, 0 = cellulosic sodium, DC only) is the pipe-root king. Its fierce, fast-freeze arc delivers the deepest penetration of any common stick rod and slices through rust, oil, paint and dirt — that’s why pipeline crews trust it for open-root joints.

E6011 swaps the coating for cellulosic potassium, which is why it runs on AC or DC+ (DCEP) instead of DC only. The arc is nearly as aggressive but far more forgiving on AC, making it a favorite for dirty steel, maintenance and farm repair. Like 6010 it’s fast-freeze, so vertical-down root passes stay keyholed and open. Polarity trips people up; our TIG welding polarity guide explains how current direction changes the arc.

Rutile and Iron-Powder Fillers: E6012, E6013 and E7014

E6012 (rutile sodium, 60,000 psi) is a flat-and-horizontal rod. It won’t win beauty contests, but it deposits fast, bridges wide gaps and poor fit-up, and runs steady on AC or DC.

E6013 is the beginner’s best friend. Its rutile-potassium coating strikes and restarts easily, holds a smooth, stable arc, and leaves a thin glassy slag that practically peels off. All-position and gentle on thin sheet, it’s the go-to general-purpose rod — and the one most schools hand a first-time student. Just remember it’s a shallow-to-medium penetration electrode, so don’t reach for it on heavy structural roots.

E7014 adds iron powder to a titania coating for 70,000 psi and an all-position filler that handles more amperage and lays more metal per pass than 6013.

Low-Hydrogen Workhorses: E7016, E7018 and E7028

E7016 (low-hydrogen, usually DC/DCEP) gives a smooth arc, low moisture and tough, clean deposits — a common choice for all-position code work. Because low hydrogen fights cracking, it’s often specified for bridges and pressure vessels.

E7018 is the structural workhorse and our second beginner-relevant pick. Low-hydrogen iron powder, 70,000 psi, all-position, and it runs on AC or DC+. Reach for it whenever quality matters or you’re welding hard-to-weld, high-sulfur or crack-prone steel. It’s hygroscopic, so keep it dry — damp rods cause porosity. For a full setup walkthrough, see our 3/16 E7018 amperage guide.

E7028 is its flat-and-horizontal-only cousin: high deposition and high current for filling thick plate.

High-Deposition Flat Shop Rods: E7024

E7024 wears a heavy iron-powder titania coating that lets it run big current and dump enormous fillets, fast. It’s flat and horizontal only — never vertical-up or overhead — but in a fabrication shop it’s a production cheat code. If you also run wire, our flux-core vs MIG breakdown shows the same deposition-versus-position trade-off.

Quick Note: If you’re new, two rods cover most of your learning curve — E6013 for easy general-purpose and thin work, E7018 when strength and quality matter.

Use this table as your aisle map:

Electrode Coating Current / Polarity Position Penetration Best Use
E6010 Cellulosic sodium DC only All Deepest Pipe roots, dirty steel
E6011 Cellulosic potassium AC or DC+ All Deep Dirty steel, repair
E6012 Rutile sodium AC or DC Flat & horizontal Medium Gap bridging, poor fit-up
E6013 Rutile potassium AC or DC All Shallow–medium General purpose, sheet metal
E7014 Iron-powder titania AC or DC All Medium Fast general fillets
E7016 Low-hydrogen DC (DCEP) All Medium Code-quality work
E7018 Low-hydrogen iron powder AC or DC+ All Medium Structural, crack-prone steel
E7024 Iron-powder titania AC or DC Flat & horizontal Shallow High-speed production fillets
E7028 Low-hydrogen iron powder AC or DC Flat & horizontal Medium Thick-plate fill

Learn these nine and the wall of codes stops being a secret. You’ll grab the right rod on the first try, then dial in the current to match. For drills that build real skill, see our welding practice guide.

Matching the Code to Polarity, Current and Machine Settings

You’ve decoded the digits. Now comes the part where paper knowledge meets the stinger: connecting the electrode holder to the right terminal and dialing in the right amperage. That last digit of the code — the coating and current indicator — is your wiring diagram. Read it wrong, and no amount of technique will rescue the arc.

DCEN, DCEP and AC in Plain Terms

Polarity is simply which terminal the electrode holder connects to. DCEN (electrode negative, or “straight polarity”) pushes more heat into the workpiece, keeping the rod cooler and producing shallower penetration. DCEP (electrode positive, or “reverse polarity”) flips that balance — more heat at the electrode, deeper penetration. AC constantly alternates between the two, which stabilizes the arc on certain coatings but limits others.

Get it backwards and the symptoms show up fast. A DCEP rod run on DCEN may stick, sputter, and lay a cold, high bead that barely fuses. A DCEN rod forced onto DCEP can blow through thin metal or overload a small electrode. Before you blame your technique, check your leads.

What Each Coating Family Wants

Here the last digit earns its reputation as the most important number in the code. Cellulosic rods demand DC: E6010 requires DCEP, and running it on AC produces a sputtering, unstable arc that stutters and refuses to carry. E6011 exists precisely because welders needed that fast-freeze cellulose arc on AC power. Basic low-hydrogen rods are more forgiving — E7018 runs correctly on AC or DCEP (reverse polarity). Rutile rods are the flexible ones; an E6013 with its rutile-potassium coating runs on AC, DC positive, or DC negative, which is why beginners and farm welders reach for it. DCEN runs cooler and suits thin-gauge rutile work where burn-through is the enemy.

Quick Note: Polarity recommendations are minimum requirements, not suggestions. An E6010 on AC isn’t a weaker version of the rod — it’s the wrong rod for that machine.

Note: Machines label the terminals “electrode” and “work.” For DCEP, the stinger goes to the positive socket; for DCEN, it goes to negative. Double-check before striking.

Amperage Scales With Diameter

With polarity sorted, set the heat. Amperage ranges scale with electrode diameter — a bigger rod carries more current. Here’s the typical E7018 window by size:

Diameter Amperage (DC+)
3/32 in 70–110 A
1/8 in 90–160 A
5/32 in 130–210 A
3/16 in 180–300 A

Those figures are a starting point, not gospel. Larger electrodes need more current and often a slightly slower travel speed to fuse properly. Match the amperage to thickness as well as diameter: the same 1/8-inch E7018 that runs beautifully at 110 A on 1/4-inch plate will burn a hole in 16-gauge sheet. When in doubt, start in the middle of the range and adjust. A quick test bead on scrap tells you more than any chart. For the biggest size, our guide to 3/16 E7018 amperage breaks down exact settings.

Read the Data Sheet Before You Strike

Every box of electrodes ships with a manufacturer data sheet listing the approved polarity, current type, and amperage range for that exact product. Coatings vary between brands even within the same AWS class, so the sheet outranks the label. Lincoln Electric’s classification guidance and Hobart Brothers’ electrode classification resources both stress that the code defines the class while the data sheet tells you how to run it. On AC, low-hydrogen rods generally need a higher open-circuit voltage to restart and maintain the arc, which is why some inexpensive buzz boxes struggle with E7018 even though the code permits AC.

If you already think in terms of polarity on other processes, the same logic applies to our TIG welding polarity guide and the flux core DCEN vs DCEP breakdown. Wire processes are no different — the reasoning carries over to gasless flux-cored setups too. Ground every decision in safe habits; our welding practice guide and shop setup guide cover the rest.

Common Mistakes, Storage and Safety When Choosing Electrodes

Even after you can read a code perfectly, careless habits will undo good choices. Most stick welding failures trace back not to the wrong number but to how electrodes were stored, handled, and run.

The Mistakes That Quietly Ruin Welds

These are the traps that catch everyone from first-week beginners to shop veterans:

  • Picking rods by sight. E6011 and E6013 share a near-identical diameter and coating color, yet one is a deep-penetrating AC/DC electrode and the other a smooth-running AC rod. Once the printed ID rubs off, you’re guessing — and guessing on a structural joint is expensive.
  • Running a DC-only rod on AC. E6010 and many E7018 grades are DC electrodes. Feed a true DC-only rod AC current and the arc stutters or dies outright. Check polarity first; our DCEN, DCEP, and AC guide explains why current direction reshapes arc behavior.
  • Mismatching tensile strength. Reaching for E6010 where the drawing specifies E7018 undercuts joint strength on higher-strength steel. Match the first two digits to the base metal’s requirement, not to whatever sits closest on the shelf.
  • Leaving electrodes exposed. Open cans and humid shops are the quiet enemy of every low-hydrogen rod.

Why Low-Hydrogen Storage Rules Exist

Low-hydrogen coatings such as E7018 pull moisture straight out of the air. In the arc that moisture breaks down and dumps hydrogen into the molten weld, raising diffusible hydrogen and sharply increasing the risk of hydrogen-assisted cracking — especially in thick, restrained joints where residual stress is already high. The fix is disciplined storage: hold opened E7018 in a rod oven at roughly 250–300°F, and re-dry damp electrodes according to the manufacturer’s classification guidance rather than guessing at temperature or time.

Smart Storage Habits

  • Keep electrodes in their original sealed container until you’re ready to weld.
  • Transfer opened low-hydrogen rods straight into a holding oven; never leave them on the bench overnight.
  • Store cellulose and rutile rods dry too — E6010, E6011, and E6013 tolerate more moisture, but damp coatings still spatter and run rough.
  • Use a portable quiver for the rods you’re actively burning, and top it up from the oven rather than carrying the whole can.

A cheap oven pays for itself the first time it prevents a cracked weld on a critical joint.

Quick Note: The words “low-hydrogen” only stay true while the rod stays dry. A soaked E7018 is just a hydrogen carrier with a label on it.

Fume, Shade, and PPE: The Safety Side

Stick welding produces heavy fume. OSHA regulates the work under 29 CFR 1910 Subpart Q, with 1910.254 governing arc welding equipment selection, installation, and instruction.

Per NIOSH, workers should position themselves to avoid breathing fume and rely on ventilation — adding respiratory protection where it isn’t enough. Eye protection matters just as much: NIOSH recommends shade 10 for SMAW with 1/16 to 5/32 in electrodes (your standard 1/8 in rod) and shade 12–14 for 3/16 to 3/8 in. Our protective eyewear guide covers lens and helmet choices in detail.

Stainless is a separate hazard. Hexavalent chromium fume can damage eyes, skin, nose, throat, and lungs and can cause cancer; OSHA’s permissible exposure limit is 5 µg/m³ as an 8-hour time-weighted average. Capture fume at the source with local exhaust, and never weld in a closed space without airflow.

Mistake-to-Solution Checklist

Mistake Fix
Rod identified by look alone Read the printed code; store rods in labeled containers
DC-only rod run on AC Confirm AC/DC capability and polarity before striking
E7018 left in an open can Return to a 250–300°F oven; re-dry per manufacturer
Tensile strength mismatched Match the first two digits to the drawing or base metal
Fume breathed in the plume Reposition, ventilate, add a respirator

Set your shop up right from the start — a properly planned workspace makes ventilation, rod storage, and safe electrode handling second nature. If you’re still building your practice, our guide to planning a safe welding shop and our welding practice guide are good next stops.

How to Pick the Right Stick Electrode in 5 Practical Steps (Plus a Quick-Reference Cheat Sheet)

So you’re back at that wall of rods, and this time the labels actually read like sentences. Let’s lock that in with a repeatable five-step decision process you can run in your head in under a minute.

Step 1: Identify Your Base Metal and Its Strength

Before you touch a single digit, know what you’re welding. Mild steel, low-alloy steel, cast iron, and stainless all steer you toward different families. Note the base metal’s approximate yield and tensile strength, its thickness, and whether it’s dirty, rusty, or clean. Matching the electrode to the parent metal is the foundation everything else sits on.

Step 2: Read the Tensile Digits to Match Reasonably

The first two digits after the E give minimum tensile strength in thousands of psi (ksi). Need to match 60 ksi steel? An E60xx or E70xx works. For most general structural mild steel, E70xx is the everyday standard, while E80xx and E100xx step up to higher-strength alloys. You don’t need to exceed the base metal wildly—just match it sensibly. For a deeper walkthrough, see our welding practice guide.

Step 3: Match Position Capability to Where You’re Welding

Are you flat on a bench or out of position overhead? The third digit tells you. A “1” means all-position; a “2” means flat and horizontal only. If you’re crawling inside a frame or welding vertical up, a 2 isn’t a debate—it’s a no-go.

Step 4: Pick the Coating/Current Digit

The last digit is the one that changes everything: penetration, deposition rate, slag behavior, and polarity. Fast-freeze cellulose rods (E6010/E6011) drive deep penetration on DC. Rutile rods like E6013 are forgiving and friendly to beginners on thin sheet. Low-hydrogen E7018 is the default for structural steel where crack resistance matters. Then confirm polarity and amperage against the manufacturer’s published operating procedures—and if polarity confuses you, our TIG welding polarity guide and flux core polarity breakdown clear it up fast.

Step 5: Check Suffixes and Confirm Storage

Optional suffixes flag extra requirements. “H4” or “H8” limits diffusible hydrogen—critical for crack-sensitive work and cold weather. “R” means the rod passed a moisture-resistance test. “-1” points to a specific impact-toughness classification. And none of it matters if the rod sat open in a damp shop: low-hydrogen rods must be stored and re-dried per the maker’s directions.

Note: No electrode choice overrides safe practice. Follow OSHA’s welding regulations and your shop’s PPE rules—proper protective eyewear included—before striking an arc.

Quick-Reference Cheat Sheet

Template: E + minimum tensile (ksi) + position + coating/current + optional suffix (H, R, -1).

What you want Pick Why
Deep penetration, root passes on pipe E6010 / E6011 Fast-freeze cellulose, forceful arc
Beginner-friendly all-position on thin sheet E6013 Soft, forgiving rutile arc
Structural steel, crack resistance E7018 Low-hydrogen, tough, all-position
Maximum deposition flat E7024 Iron-powder, heavy fill
High-strength alloy steel E80xx / E100xx Matches stronger base metal

Beyond the table, the fastest rule of thumb: dirty or rusty steel and deep roots want E6010/E6011; clean sheet and shaky hands want E6013; serious structural work wants E7018; and high-production flat filling wants E7024.

Quick Note: On code work, a qualified Welding Procedure Specification (WPS) governs electrode selection—personal preference doesn’t. The American Welding Society and electrode classification guides are your reference when a job calls for specific testing.

The code is a specification, not marketing—it tells an inspector, a WPS, and you exactly what the rod is built to do. Read it left to right: tensile, position, coating, suffix. Match the metal, mind the position, respect the coating, and check the extras. When in doubt, the manufacturer’s data sheet knows more than any forum thread, and the WPS on a code job always wins. Save this cheat sheet, tape it inside your hood, and the next time the counter guy asks, you’ll answer with certainty instead of a shrug. Now go pick a rod on purpose.

Frequently Asked Questions

What do the numbers on a stick electrode mean?

On a typical carbon steel rod like E7018, the E means electrode, the 70 is the minimum tensile strength in thousands of psi (70,000 psi), the 1 means it can be used in all positions, and the 8 identifies the coating type and the current/polarity to use.

What does the 70 mean in E7018?

The 70 means the deposited weld metal will meet a minimum tensile strength of 70,000 psi (about 480 MPa). It is a minimum mechanical property specified by AWS A5.1, not the strength of the base metal.

Does E7018 mean all position?

Yes. The next-to-last digit tells the position: 1 means all positions (flat, horizontal, vertical, overhead), and 2 means flat and horizontal only. In E7018 the 1 confirms it is an all-position electrode.

What is the difference between E6010 and E6011?

They look almost identical and both use a cellulosic coating, but E6010 uses a sodium coating and runs on DC electrode positive only, while E6011 uses a potassium coating that also runs on AC. Both give deep penetration and are used for pipe roots.

Can I use E7018 on AC?

Yes, E7018 is designed to run on both AC and DCEP (reverse polarity). However, E6010 is DC-only and will run poorly on AC, so always check the last coating digit and the manufacturer’s data before choosing a current.

What does the H4 in E7018 H4R mean?

H4 means the electrode is rated for a maximum of 4 mL of diffusible hydrogen per 100 g of weld metal. The R means it also passed an absorbed-moisture resistance test. Lower hydrogen reduces the risk of cracking in high-strength steel.

Why do low-hydrogen electrodes need to be stored in an oven?

Low-hydrogen rods like E7018 absorb moisture from the air once opened, and that moisture introduces hydrogen into the weld, which can cause cracking. Storing them in a holding oven and re-drying them per manufacturer instructions keeps hydrogen at safe levels.

Which stick electrode is best for beginners?

E6013 is often recommended for beginners because of its stable, forgiving arc and easy slag removal, and it works in all positions on clean material. E7018 is a common second step for structural work once you can control the arc.

Authoritative Sources & Further Reading