3/32 E7018 Amperage: Settings, Polarity & How to Run It
My first E7018 rod went about as badly as a weld can go without catching fire. I was…
READ ARTICLE →You pull a spool off the shelf labeled E71T-GS, grab another stamped E71T-11, and pick up a third that reads E71T-1C H8. Same grey wire. Same spool. Same machine. Yet one will run beautifully on your project, one lays down porous, cracking welds, and one might not run at all on the polarity you already have set. Choosing the wrong one isn’t a nuisance. It can void a structural weld or waste an entire spool.
Here’s the truth those identical-looking labels hide: flux core wire is a family of electrodes, not a single product. Treat it like one brand of filler metal and you’ll eventually grab the wrong spool at the worst possible moment.
Flux-cored arc welding (FCAW) is one of the most widely used arc welding processes in the United States today, and flux-cored wires have been commercially available since the 1950s. The process looks a lot like MIG, so newcomers often assume the wire is the same too. It isn’t. If you’ve ever wondered whether flux core is the same as MIG, the short answer is no—and the spool is where the differences start.
A flux-cored electrode is a tubular wire. A thin steel sheath is formed into a tube and filled with a powdered flux core that carries alloys, deoxidizers, gas formers, and slag formers. When the arc burns, that fill does several jobs at once: it creates shielding, stabilizes the arc, adds alloying elements, and forms a slag blanket that protects the cooling weld.
Quick Note: The hollow construction is the whole story. Two wires can share the same steel sheath and the same diameter yet behave completely differently because of what’s packed inside.
Flux core splits into two main lineages:
That single distinction explains most of the confusion on the shelf, and it’s where self-shielded and gas-shielded electrodes part ways in both performance and application.
Every classification follows standards like AWS A5.20 and AWS A5.36, which encode strength, position, shielding type, and usability. Those usability designators—T-1, T-8, T-11, T-GS and friends—tell you how a wire runs, whether it’s self-shielded or gas-shielded, and what polarity it wants. Get polarity backwards and even a good wire welds badly, which is exactly why we cover DCEN versus DCEP as its own topic. Most self-shielded wires run on DCEN while most gas-shielded wires run on DCEP—mix them up and the arc turns ugly fast.
Wire choice drives more than convenience. It sets your deposition rate, your toughness, whether you can weld out of position, and whether a joint meets its code. A wire that’s perfect for a windy fence line can be flatly unapproved for a pressure vessel.
This guide walks through the classification system, the self-shielded and gas-shielded families, low-alloy and stainless options, every designator, settings and polarity, the real trade-offs, common mistakes, and a simple framework for choosing. By the end, those three identical spools will never look the same again. That’s the difference between a weld that passes inspection and one that fails it.
Those codes on the spool aren’t random. Every flux core wire follows a classification system defined by the American Welding Society (AWS), and once you crack the pattern, you can read any label in seconds.
Take a common wire like E70T-1C from AWS A5.20/A5.20M. Here’s how it breaks down:
The first two digits aren’t a fixed menu. A 70 covers mild steel, while 80, 90, and higher series serve stronger steels. The position digit is just as practical: a “0” wire deposits fast in flat and horizontal work, while a “1” wire holds a puddle overhead and vertically.
Notice what’s missing: diameter and polarity live on the data sheet, not in the classification, which is why two identical part numbers can behave very differently if you set them up wrong.
That single extra letter matters a lot. A C wire and an M wire of the same number are not interchangeable—each is qualified only with its designated gas.
The usability designator after the dash (the “1”) tells you how the wire behaves. We cover each one in depth later, but the letter suffixes pack more information:
That toughness point trips people up, so remember this: a “9” wire must meet 20 ft-lbf at -20°F (27 J at -29°C), while a “1” wire only needs 20 ft-lbf at 0°F (27 J at -18°C). Since the “9” test is tougher, a T-9 can also satisfy T-1 requirements—but never the other way around.
Quick Note: if a drawing specifies E71T-1, an E71T-9 wire is a legal substitute (it meets and exceeds the toughness), but an E71T-1 is not a substitute for E71T-9.
Lincoln Electric publishes a useful breakdown of how these usability designators affect arc behavior.
There are two families of specs. The traditional fixed systems—AWS A5.20/A5.20M for carbon steel (2021, with a 2025 edition) and A5.29 for low-alloy steel—lock each classification to a specific combination of shielding gas and usability. These are the numbers most shops and drawings still quote.
Then there’s AWS A5.36/A5.36M, the “open” system. It decouples the variables so you can specify properties independently, and it retains the older fixed classifications for backwards compatibility. A5.36 also introduced T-15 for metal-cored electrodes and T-16 and T-17 for AC-capable wires. The EXXT-2X and EXXT-13 classes were dropped back in the 2012 edition.
Many wires are dual- or tri-classified—printed as something like E71T-1C / E71T-9C / E71T-12C—meaning one spool satisfies several part numbers. That flexibility is convenient, but always confirm the letter suffix and gas match your procedure.
Finally, don’t confuse the two families on the shelf. Metal-cored wire carries the T-15 designator and looks similar, but it’s a distinct product that runs on a different transfer mode and typically needs a gas shield. For a hands-on walkthrough of setting up a wire machine, see our beginner’s guide to wire welders.
Also worth checking polarity early: most self-shielded wires run DCEN while gas-shielded wires run DCEP. Get it backwards and even a premium wire will sputter, ball up, or burn through, so read our comparison of DCEN vs DCEP for flux core welding before you strike an arc. If you’re running gasless, our flux-cored welding without gas guide covers the setup differences.
Self-shielded flux core wire is the wire that travels light. There’s no gas cylinder, no regulator, no hose—just a spool and a machine. The flux inside the tubular wire carries its own shielding, which is why this family is often called “gasless” wire and why it shows up on wind-whipped job sites where a shielding gas cloud would blow away before it could protect the weld pool.
When the arc strikes, the flux core decomposes under the heat and releases a blanket of gas—carbon dioxide, carbon monoxide, and hydrogen—around the molten metal. That envelope pushes atmospheric oxygen and nitrogen away from the weld pool. The remaining slag then forms on top, insulating the bead as it cools.
Because the shielding comes from the wire itself, self-shielded wire shrugs off wind that would ruin a gas-shielded weld. You can run it outdoors, on a ladder, or twenty feet off the ground without dragging a bottle along. That portability is why it dominates field work, pipe repair, and structural erection. For a full breakdown of the gasless approach, see our guide to gasless MIG welding.
To activate the flux, most self-shielded wires run DCEN (electrode negative) and need a long electrode extension—often up to about 3/4 in—so resistance preheats the wire before it enters the arc. That long stick-out is unusual compared to MIG, but it’s essential here. If you get the polarity backwards, the wire sputters, spatters, and the flux never fully does its job. Our article on polarity for flux core welding walks through the DCEN versus DCEP details.
The trade-off is penetration. Self-shielded wire tends to produce shallower penetration than gas-shielded flux core, because the arc energy is spread over a wider area.
Self-shielded wires lean heavily on deoxidizers and denitrifiers—aluminum and titanium mostly—to capture stray oxygen and nitrogen. E70T-8 flux, for example, runs roughly 15.4% aluminum to fight contamination.
The distinction between T-11 and T-8 is where most real-world decisions get made. T-11 is forgiving and cheap to run, but it trades away toughness. T-8 costs more and demands more care—clean surfaces, controlled settings—but it passes the impact and seismic requirements that structural codes care about. If a drawing specifies demand-critical welding, T-11 won’t get you there.
Quick Note: Self-shielded FCAW runs a deposition efficiency of roughly 65–70%, versus 80–85% for gas-shielded FCAW. More of the wire leaves as fume and slag, but output is still respectable—about 8.5 lb/hr at 300 A with 1/16 in wire.
The long electrode extension wears contact tips faster than a standard MIG setup, so inspect and swap them regularly; our guide to contact tip welding covers the wear signs.
Gas-shielded flux core wire, nicknamed “dual shield,” pairs an internal flux core with an external shielding gas fed through the gun. The flux does part of the work; the gas does the rest. It’s the workhorse of fabrication shops and structural steel, and for good reason: it lays down metal fast, penetrates deeply, and produces beads that look machine-laid even when they weren’t. That combination makes it the go-to process on thick plate, long production runs, and joints where deep fusion matters more than a pretty finish. It’s a different animal from the gasless wires covered in our gasless MIG welding guide.
If you’re weighing this against solid-wire MIG, start with Is Flux Core the Same as MIG? before choosing a spool.
FCAW-G wires run on DCEP (electrode positive), the reverse of most self-shielded wires. Get it wrong and the arc goes weak and spattery, so confirm the DCEN vs DCEP setup for your exact wire. Many machines ship with the leads set for solid wire, so it pays to double-check polarity before you strike an arc.
Shielding gas is folded into the classification code:
So E71T-1C is a CO2 wire; E71T-1M is the mixed-gas version. The AWS usability designators spell this split out in the suffix. The mix is the shop default, thanks to a cleaner arc and tidier bead, while CO2 stays popular for heavy plate and deep-penetration work.
Quick Note: A dual-shield wire doesn’t shield itself. Leave the gas off and you’ll get porosity that looks like worm tracks. No amount of technique fixes missing gas.
Each “T” number describes how the wire runs, not how strong it is:
Rutile wires (T-1, T-9, T-12) give low spatter, a stable arc, and slag that covers the bead evenly and chips off easily. They’re a pleasure to run, which is why they dominate general fabrication. Basic slag wires like T-5 trade that comfort for superior mechanical properties, including better impact toughness and crack resistance for critical structural joints. Expect a rougher arc and slag that fights you on removal. This one rewards practice.
Dual shield earns its place through speed. About 80% of the consumable weight becomes weld metal, and gas-shielded FCAW efficiency runs in the mid-to-high 80% range. A representative 1/16 in. wire at 300 A deposits roughly 10.5 lb/hr, about 25% more than a comparable self-shielded wire. That gap is why it’s the backbone of production fabrication.
The catch is the gas. Because the shield is external, wind above roughly 5 mph strips it away and leaves porosity behind. That single fact tells you where this process belongs: indoors, in a fab shop or a shielded structure. Take it outside in a breeze and you’ll need windbreaks, or a self-shielded wire instead. For set-up guidance, see our welding facilities planning guide.
Most conversations about flux core wire start and stop at E71T-11 or E71T-GS. That’s a shame, because the tubular electrode family reaches far past mild steel. Flux-cored wires are available for mild steel, low-alloy steel, stainless steel, nickel alloys, and hardfacing, in both self-shielded and gas-shielded versions. These are the wires running in food plants, chemical refineries, pressure vessels, and mining equipment. If you only ever stock one 70 ksi carbon wire, you’re leaving capability on the table.
Low-alloy flux-cored electrodes are classified under AWS A5.29 or the newer A5.36 specification. The suffix tells you what the alloy system buys you.
Quick Note: A 70 ksi wire and an 80 ksi wire may look identical on the spool, but mismatching strength to a qualified procedure is a code violation, not a shortcut.
Stainless flux-cored electrodes are classified under AWS A5.22 and, increasingly, A5.36, covering austenitic grades like 308L, 309L, and 316L plus duplex grades such as 2209. The “L” means low carbon, which resists sensitization and intergranular corrosion. Many are gas-shielded, typically running on a CO2 or argon-CO2 mix, though self-shielded stainless versions exist for field work and repair. Duplex wires are fussier: they need controlled heat input to preserve the ferrite-austenite balance that gives them their stress-corrosion resistance.
One thing you must respect: the fume. Stainless and surfacing wires release chromium, manganese, and nickel in the fume, and hexavalent chromium is a known carcinogen. Good ventilation and proper protective gear aren’t optional here. The OSHA guidance on welding fume is worth reading before you commit to a stainless job.
Nickel-alloy flux-cored wires fill the gap where even stainless isn’t corrosion-resistant enough. They show up on nickel-based alloys, dissimilar joints, and components facing severe acids or high heat. They’re a niche spool, but when a job calls for them, nothing else substitutes. For dissimilar work that involves aluminium, the rules change entirely — see our guide to DC welding aluminium.
Hardfacing wires are a different animal. They have no single AWS usability classification, because they’re not selected for strength — they’re selected for deposit hardness and wear resistance. You’ll find them in gas-shielded and self-shielded versions across a wide range of deposit hardness, from roughly 20 HRC for build-up to 60+ HRC for severe abrasion and metal-to-metal wear. Bucket teeth, crusher rolls, and excavator lips live and die by these.
Selection comes down to three questions:
Get those three right and you’ll rarely reach for the wrong spool. Good welding practice starts before you pull the trigger — and when in doubt, check the base metal cert against a filler metal selection chart before you order.
The dash number after the “T” is the usability designator, and it is the most useful character in the whole classification. AWS A5.20/A5.20M groups electrodes by similar operating characteristics, so that number tells you the shielding method, the polarity, which positions the wire can weld, whether it handles single or multiple passes, and roughly how it feels to run. As Lincoln Electric’s designator reference explains, usability designators may run from 1 through 14, or appear as G or GS, each indicating a general grouping of similar characteristics.
Here’s the master decoder. If you memorize one thing from this article, make it this table.
| Designator | Shielding | Polarity | Positions | Passes | Typical role |
|---|---|---|---|---|---|
| T-1 | Gas | DCEP | All | Multi | Workhorse gas-shielded wire |
| T-2 | Gas | DCEP | Flat & horizontal | Multi | High-deposition shop work |
| T-3 | Self | DCEN | Flat & horizontal | Single | Fast, simple gasless runs |
| T-4 | Self | DCEN | Flat & horizontal | Multi | Higher deposition than T-3 |
| T-5 | Gas | DCEP | All | Multi | Toughness-focused gas wire |
| T-6 | Self | DCEN | All | Multi | All-position impact work |
| T-8 | Self | DCEN | All | Multi | Higher impact toughness |
| T-11 | Self | DCEN | All | Multi | Gasless structural favorite |
| T-14 | Self | DCEN | All | Multi | Versatile, different chemistry |
| T-GS | Self | DCEN | All | Single | General-spec consumer wire |
Every designator falls into one of two families. The gas-shielded group is T-1, T-2, T-5, T-9, and T-12; these all run DCEP and require an external shielding gas. The self-shielded group is T-3, T-4, T-6, T-7, T-8, T-10, T-11, T-13, and T-14. The letters G and GS can appear in either family, depending on the manufacturer’s intent.
On a self-shielded wire, the flux inside the tubular electrode creates its own shielding cloud as it burns, so no gas cylinder is needed. That’s the world covered in our guide to gasless MIG welding. Whichever branch you run, polarity is the first thing to get right — see Polarity for Flux Core Welding: DCEN vs DCEP.
T-1 is the most common gas-shielded designator. It runs DCEP, welds all positions, and handles multi-pass joints. A “C” in the classification means it is qualified for 100% CO2; an “M” means an argon/CO2 mix. So E71T-1C runs on straight CO2 while E71T-1M wants the mix.
T-2, T-5, and T-9 are also gas-shielded DCEP wires, tuned for specific deposition or toughness goals. T-2 is generally a flat-and-horizontal performer aimed at laying metal down fast.
T-11 is the one most home and field welders meet. E71T-11 runs DCEN, welds all positions, and handles multi-pass joints — a genuinely structural-capable gasless wire. That’s the key difference from its lookalike, T-GS.
T-6, T-8, and T-14 are self-shielded, all-position, multi-pass wires formulated for tougher impact requirements. T-3 and T-4 are the simpler flat-and-horizontal self-shielded numbers, best for single or light multi-pass work where deposition speed matters more than position flexibility.
Quick Note: A spool can carry more than one designator. A dual or triple classification like E71T-1C/1M or E71T-11/GS means the wire met the tests for each listed group. Match the strictest designator your code requires.
G and GS stand for “general specification” — and unlike the numbered designators, they carry no fixed requirement set. A manufacturer can certify a wire as G or GS without proving a defined polarity, position range, or pass count. That loophole is why consumer E71T-GS is DCEN and all-position yet single-pass only. It runs beautifully on one clean pass over thin steel, but it is not meant for stacked structural joints.
Trailing letters and numbers refine the chemistry and toughness guarantees:
These suffixes are where electrodes like E71T-1C H8 and E71T-1M-JH4 earn their long names. Every designator, though, only behaves as intended when the rest of the consumable ecosystem is healthy, from the feed rolls to the contact tip that carries current into the wire.
You can buy the correct electrode and still ruin the weld with the wrong setup. Flux core is fussy about three things your machine controls: wire diameter, polarity, and gas. Get them right and the wire runs smooth. Get them wrong and you get spatter, porosity, or an arc that stutters and sticks.
Common flux core diameters run from 0.030 in up to 5/64 in, with 3/32 in occasionally used for heavy fabrication. Diameter drives how much current the wire carries and how much metal you lay down.
So the rule is simple: small wire for thin steel and low-amperage work, large wire for high-deposition flat welding. If feeding and dragging a bead still feels awkward, the fundamentals in our guide to how to use a wire welder will steady your hand before you chase bigger diameters.
This is where beginners lose whole spools. Self-shielded (FCAW-S) electrodes almost always run on DCEN (electrode negative). Gas-shielded (FCAW-G) electrodes almost always run on DCEP (electrode positive). Run a self-shielded wire on DCEP and you flip the burn-off behavior, producing an erratic arc, heavy spatter, and poor penetration. The classification stamped on the wire tells you which polarity it expects, and the AWS filler metal specs spell out those requirements — see AWS A5.20/A5.20M for carbon steel flux cored electrodes.
Quick Note: Always confirm polarity on the spool label or data sheet before striking an arc. Swapping leads takes seconds; a failed weld test costs hours. If you’re unsure which lead goes where, our explainer on polarity for flux core welding walks through lead placement step by step.
FCAW-G needs external shielding gas, usually CO2 or a CO2/argon blend. The recommended flow rate is roughly 35–45 CFH at the nozzle. Too little and you invite porosity; too much and you create turbulence that pulls air into the puddle. Indoors, that range is easy to hold. Outdoors, a breeze can blow the shield away no matter how high you set the regulator, so build a windbreak or move upwind. Note that self-shielded wires generate their own protection and must not be used with shielding gas — as Lincoln Electric explains in its guide to self-shielded versus gas-shielded electrodes.
Electrode extension (stickout) is critical and differs by type. For self-shielded T-11 wire, a 1/2- to 3/4-in stickout with a 10–20 degree drag angle helps minimize slag inclusions and improves penetration. Gas-shielded wire wants a short stickout — typically 3/8 to 3/4 in — to keep the gas envelope intact. Self-shielded electrodes can actually require extension up to about 3-3/4 in to properly activate their flux chemistry.
Use these as a starting point only. Typical T-11 (self-shielded) settings run about 17–22 volts and 50–275 amps depending on diameter.
| Wire | Polarity | Voltage | Amperage |
|---|---|---|---|
| 0.030 in T-11 | DCEN | 17–19 V | 50–130 A |
| 0.035 in T-11 | DCEN | 18–20 V | 90–180 A |
| 0.045 in T-11 | DCEN | 19–22 V | 130–275 A |
| 0.045 in T-1 (gas-shielded) | DCEP | 22–28 V | 150–260 A |
Treat every number here as a reference, not a recipe. The manufacturer’s recommendation and a qualified welding procedure specification (WPS) govern the job, especially on structural work. Dial in wire speed and voltage to the sound of the arc, keep your contact tip and liner clean, and the wire will do exactly what its classification promises.
Flux core wire earns its place on the truck for stubborn reasons. It lays down metal fast, welds well out of position, tolerates rusty or lightly coated plate, and lets one process handle root through cap. Those advantages come with a real bill, and understanding it is how you decide when flux core is the right call and when solid wire, stick, or metal-cored wire is smarter.
Deposition is the headline. Continuous wire feed plus high current puts down far more weld metal per hour than a stick welder swapping electrodes every few inches, which is why flux core dominates field work, structural steel, and repair jobs where travel time matters. It also runs capably in flat, horizontal, vertical, and overhead positions, something few single processes manage.
Tolerance is the second draw: flux-cored electrodes shrug off mill scale and light rust that would send a solid MIG bead into porosity, so compare what good and bad MIG welds look like for contrast. Third is simplicity. One wire, one machine, and no bottle to drag around if you run self-shielded. If you’re still sorting out which process you own, the differences between flux core and MIG are worth settling first.
Both variants deposit quickly, but they trade blows on everything else. Self-shielded electrodes carry their own shielding in the flux, so they resist wind and work outdoors without gas. Gas-shielded electrodes run smoother arcs, spit less spatter, and appeal more to operators, but a breeze will wreck the shielding. Polarity flips between the two families as well: most self-shielded wire wants DCEN, while most gas-shielded wire wants DCEP. Getting that backwards changes everything about how the wire runs.
| Factor | FCAW-S | FCAW-G |
|---|---|---|
| Wind tolerance | Excellent | Poor |
| Operator appeal | Harsher arc | Smoother, less spatter |
| Deposition efficiency | ~65–70% | ~80–85% |
| Wire cost per pound | Higher | Lower (plus gas) |
Deposition efficiency is where gas-shielded wins: it converts more of the wire into weld metal, losing less to slag and spatter. For reference, solid MIG wire converts about 98% of consumable into weld metal.
Fume is flux core’s least flattering trait. OSHA lists flux-cored arc welding first among common arc processes in decreasing order of fume production, and a controlled study confirmed FCAW generates more fume than GMAW at an equal strength class. Self-shielded wire produces the most, because its flux does the entire shielding job. Raising welding current and raising CO2 content both push fume generation higher.
Quick Note: Because self-shielded wire makes the most fume, plan extraction and respiratory protection before the spool goes on. Good welding facilities make that far easier.
Every flux core pass leaves slag that must be chipped and brushed away before the next one, or you risk trapping it as a defect. That slag also hides the bead, so inspection carries more weight. Flux that flows ahead of the puddle can leave an overlap defect, which looks fine until it is loaded.
Gas-shielded wire is typically cheaper per pound, but you pay for shielding gas and the logistics that come with it. Self-shielded wire contains more alloying elements and costs more per pound, yet saves on gas and works where a bottle is impractical. Real cost is total: wire plus gas plus cleanup labor plus fume control. Stick offers cheap equipment but slow deposition and heavy cleanup. Solid MIG is clean and efficient but fussy about surface prep. Metal-cored wire deposits fast with less slag, at a premium price.
Most of the grief welders run into with flux core isn’t the wire’s fault. It’s a mismatch between the wire and the way it’s being run. Here are the mistakes that cost people the most, followed by the safety problems that actually matter.
Adding shielding gas to a self-shielded wire. This is the big one. A self-shielded electrode like E71T-8 or E71T-11 carries its own flux and shields the arc from the inside out. Flooding it with CO₂ or argon changes the arc chemistry and is simply forbidden. The aluminum added as a deoxidizer, roughly 15.4% in E70T-8, is meant to react with air. With gas covering the arc it never gets consumed, stays in the deposit, and forms brittle intermetallic compounds. The result is brittle weld metal, cracking, porosity, and worm tracks. For more on the gasless process, see our guide to gasless MIG welding.
Setting the wrong polarity. Self-shielded wires generally run on DCEN (straight polarity), while most gas-shielded wires want DCEP. Run the wrong one and the arc sputters, penetration drops, and spatter climbs. Our breakdown of polarity for flux core welding walks through which wire needs which.
Quick Note: If a weld comes out porous and you changed nothing, check the wind and your gas flow before you blame the wire.
Flux core welding fume isn’t just nuisance smoke. Chromium-bearing wires can release hexavalent chromium, and OSHA sets its permissible exposure limit at 5 micrograms per cubic meter as an 8-hour time-weighted average. Self-shielded fluxes can also put manganese and barium into the air, and manganese overexposure is linked to neurological effects. Fume is the reason ventilation is a non-negotiable part of the setup.
A movable local exhaust hood should hold a capture velocity of about 100 linear feet per minute in the welding zone, with in-line duct velocities above 3,000 ft/min so airborne particles don’t settle in the duct. NIOSH research shows properly positioned local exhaust can cut welder exposure by 40-50% or more compared with natural ventilation alone. In enclosed spaces, general ventilation is often sized around 2,000 CFM per welder. When ventilation still can’t bring exposure below the limits, a respirator is required, not optional.
Don’t forget arc radiation. A proper helmet, filter lens, and skin cover keep UV and IR off your eyes and arms; our guide to protective eyewear for welding covers lens shades. Expectant welders need extra caution too, which is why we wrote can you weld while pregnant.
Good welding facilities start with airflow you control, clearly posted polarity per machine, and a shelf where each spool is labeled with its classification. Get the wire, the setup, and the ventilation right, and most “bad wire” problems quietly disappear.
After ten sections of classifications, designators, and trade-offs, the choice usually comes down to four questions. Ask them in order and the right spool almost picks itself.
If you’re in a shop with a reliable gas supply and no wind, gas-shielded FCAW-G wins on deposition and weld appearance. For general fabrication, reach for E71T-1C (CO₂) or E71T-1M (CO₂/argon mix). Running flat or horizontal and chasing maximum deposition? E70T-1 is built for it. Demanding toughness on thicker sections points to a T-5 electrode.
Out-of-position field work with no gas points to E71T-8, a self-shielded wire valued for its consistent all-position behaviour. Heavy flat fabrication in a shop, by contrast, rewards a gas-shielded high-deposition wire where speed matters more than portability.
No gas, or welding outdoors in wind? Switch to self-shielded FCAW-S. The self-shielded versus gas-shielded comparison makes the split plain: gas wires rely on external shielding, self-shielded wires generate their own.
If the work falls under a code such as AWS D1.1, the wire must be one the code recognizes. E71T-1C is prequalified under AWS D1.1 and is the standard gas-shielded structural wire. For self-shielded code work, E71T-8 meets AWS D1.1 and AWS D1.8 seismic requirements. Never substitute a hobby wire for a coded joint; changing between separate AWS classifications, for example from FCAW-G to FCAW-S, can require additional testing and qualification.
For stainless, hardfacing, or low-alloy work, choose the matching alloy classification rather than forcing a mild-steel wire to do a job it wasn’t built for. Two practical checks remain. Match the wire diameter to your material thickness and machine capability, and keep spare contact tips on hand since flux core wire wears them faster than solid wire. A quick review of contact tip selection and wear saves a lot of troubleshooting.
One more check: polarity. If your machine offers only one setting, match the wire to it. Self-shielded wires run on DCEN (electrode negative), while gas-shielded wires want DCEP. Get this backwards and you get spatter, poor penetration, and porosity, a point covered in detail in our guide to polarity for flux core welding.
Quick Note: Every classification lets you verify the basics yourself: tensile strength (70 ksi for “71”, 80 ksi for “81”), position (0 for flat/horizontal, 1 for all-position), and the usability designator. Confirm them on the spool before you buy.
| Wire | Shielding | Polarity | Positions | Multi-Pass | Tensile | Code Status |
|---|---|---|---|---|---|---|
| E71T-GS | Self | DCEN | All | No (single-pass) | 70 ksi | Not for code work |
| E71T-11 | Self | DCEN | All | Yes | 70 ksi | Limited/general |
| E71T-8 | Self | DCEN | All | Yes | 70 ksi | D1.1 & D1.8 |
| E71T-1C | Gas (CO₂) | DCEP | All | Yes | 70 ksi | Prequalified D1.1 |
| E71T-1M | Gas (mix) | DCEP | All | Yes | 70 ksi | Prequalified D1.1 |
| T-5 | Gas | DCEP | All | Yes | 70–80 ksi | Toughness-critical |
| Low-alloy grades | Self or gas | Varies | Varies | Yes | 80+ ksi | Per application |
Whatever you choose, follow the Welding Practice rules for technique and settings, verify the classification on the spool, and trust the WPS over any shortcut. The journey from bare rod to today’s engineered wire is long, as the history of MIG welding shows. Start with the four questions, and let the code, the gas, and the position guide the rest. Practice is what turns the right spool into a right weld.
Self-shielded wire (FCAW-S) generates its own shielding gas from the flux core and needs no external gas cylinder, so it works outdoors in the wind. Gas-shielded (dual-shield) wire (FCAW-G) relies on an external supply of 100% CO2 or an argon/CO2 blend and is generally used indoors for higher deposition and cleaner welds.
No. Both are self-shielded all-position wires that run on DCEN, but E71T-11 is rated for multi-pass structural joints while E71T-GS is a single-pass-only wire. Use E71T-11 for anything requiring multiple passes or code work, and E71T-GS only for light single-pass welds and repairs.
Most self-shielded flux core wires run DCEN (electrode negative), including E71T-11, E71T-8, and E71T-GS. Gas-shielded wires such as E71T-1C and E71T-1M run DCEP (electrode positive). Always confirm polarity for your specific classification, because using the wrong polarity produces a poor, unstable arc.
No. Using external shielding gas with self-shielded wires like E71T-8 or E71T-11 is forbidden because it disrupts the carefully balanced flux chemistry. The excess deoxidizers such as aluminum are not consumed by reacting with air and can form brittle compounds, leading to cracking, porosity, and worm tracks.
The dash number is the AWS usability designator, which tells you the wire’s shielding system, required polarity, position capability, and general operating characteristics. Self-shielded wires use designators such as T-6, T-8, T-11, and T-14, while gas-shielded wires use T-1, T-2, T-5, T-9, and T-12.
Yes, when the correct classified wire is selected and the work is done under a qualified welding procedure. E71T-1C is prequalified under AWS D1.1 for gas-shielded work, and E71T-8 is a low-hydrogen self-shielded wire used for AWS D1.1 and AWS D1.8 demand-critical seismic welds. General-purpose E71T-11 has limits, such as AWS D1.1 restricting it to material under 1/2 in thick.
The flux burns and decomposes to create slag and shielding gas, which generates significantly more fume than solid MIG wire—often two to three times as much. OSHA lists flux-cored arc welding first among common arc processes in decreasing order of fume production, and fume output rises with both higher current and higher CO2 content.
For a 110V or 230V hobby machine with no gas cylinder, a 0.030 to 0.035 in E71T-11 wire is the most forgiving all-around choice because it is self-shielded, works in all positions, and handles multi-pass joints. E71T-GS is acceptable for very light single-pass work but is more limited.
Flux core wire contains flux that forms slag and, in self-shielded grades, shielding gas. Metal-cored wire has a similar tubular shape but a metallic powder fill with little to no slag, so it produces cleaner welds and higher deposition with fewer fusion defects. Metal-cored electrodes carry usability designator T-15 under AWS A5.36 and are used in GMAW.